Sensor Type | Electrochemical |
---|---|
Compliance | UL 2034 |
Operating Temperature | 40°F (4.4°C) to 100°F (37.8°C) |
Operating Humidity | 10% to 95% (non-condensing) |
Weight | 0.5 lbs |
Unit alarms at 150 ppm CO within 50 minutes.
12VDC nominal power supply.
Standby 20 microAmp, Alarm 60 mA, Trouble 30 mA.
Uses 14-22 AWG wire for field connections.
Dry form 'C' (100 microAmp – 0.1A, 12VDC) non-latching.
Operates between 4.4° C - 37.8° C (40° F - 100° F).
Functions within 15-95% RH.
Audible alarm at 85 db @ 10 ft (3.3 meters).
Alarm is designed for six years of operation; automatic sensing and loud sounder.
Statistics show fatal CO occurrences happen at night; early warning is key.
Place alarms inside each bedroom where occupants close the door while sleeping.
Mount close to hallway center, or at least 4 inches from any wall.
Avoid cooking appliances, open windows/doors, damp areas, and extreme temperatures.
Includes venting issues, negative pressure, appliance use, and obstructions.
Align marks, twist alarm onto plate until locked, and secure with tamper pin.
Use provided pin to deter removal; use pliers to remove.
RED LED flashes once every 30 seconds, indicating power.
RED LED, 4 short beeps, relay energized; test/reset silences for 4 mins.
Detector beeps, Indicator/Test button flashes twice if fault detected.
Clean with vacuum cleaner hose; do not wash or use chemicals.