Do you have a question about the Cosworth Omega ICD and is the answer not in the manual?
The Cosworth Omega ICD (Intelligent Colour Display) is a sophisticated, full-colour display unit designed for use in a wide range of vehicles, particularly in motorsport applications. It provides a comprehensive suite of data logging, display, and control features, all housed within a robust and compact enclosure.
The Omega ICD serves as a central hub for vehicle data, offering a highly configurable display and powerful data logging capabilities. It can display a variety of information, including engine parameters, lap times, alarms, and other critical vehicle data, all presented on a vibrant, anti-reflective colour screen. The display is designed to be easily readable in various lighting conditions, including direct sunlight, thanks to its high brightness and contrast.
The device features a powerful 6.2" TFT display with a resolution of 800 x 480 pixels and a contrast ratio of 600:1. The screen offers a luminance of 4000cd/m², ensuring excellent visibility. The display also incorporates a hard antiglare coating and a 70-degree viewing angle, further enhancing readability.
One of the key features of the Omega ICD is its extensive data logging capability. It includes 1GB of memory, allowing for approximately 1 hour of logging at 50KB/s. This memory is expandable, and the device supports various logging rates. The ICD can log data from multiple sources, including its internal sensors, external CAN bus devices, and connected analogue and digital inputs.
The ICD is equipped with a powerful Freescale i.MX27 processor, enabling it to handle complex calculations and data processing. It runs on a Linux operating system, providing a stable and flexible platform for its various functions. The device also includes an Ethernet port, allowing for high-speed data transfer and network connectivity.
The Omega ICD offers a wide range of configurable features. Users can customize the display layouts, alarm thresholds, and shift light patterns to suit their specific needs. The device supports multiple display pages, allowing users to quickly switch between different sets of information. The shift lights are user-configurable, providing visual cues for optimal gear changes.
The device also includes an integrated lap beacon receiver, allowing for accurate lap timing and sector analysis. This feature is particularly useful in motorsport applications, where precise timing is crucial. The ICD can display lap times, best laps, and other timing-related data, providing drivers with real-time feedback on their performance.
The Omega ICD is designed to be highly versatile, supporting a variety of input and output options. It includes multiple analogue and digital inputs, allowing it to interface with a wide range of sensors and external devices. The device also features multiple CAN bus ports, enabling it to communicate with other vehicle systems and log data from them.
The device supports various communication protocols, including RS232 serial ports and USB. These interfaces allow for easy configuration, data download, and firmware updates. The ICD also includes a built-in battery voltage monitoring system, ensuring reliable operation.
The Omega ICD is designed for ease of use and high configurability. The display layouts can be fully customized using Cosworth's Pi Toolbox PC software, allowing users to create bespoke screens tailored to their specific data requirements. This software also enables the configuration of alarms, shift lights, and other device settings.
The device features user-configurable alarm LEDs and shift LEDs, providing clear visual feedback to the driver. These LEDs can be programmed to illuminate based on various parameters, such as engine RPM, oil pressure, or water temperature, alerting the driver to critical conditions or optimal shift points.
The Omega ICD's robust construction and IP65 environmental protection make it suitable for harsh environments, including motorsport applications. It is resistant to dust, water, and vibrations, ensuring reliable operation in demanding conditions.
The device's multiple input and output options allow for seamless integration with a wide range of vehicle systems. It can connect to engine control units (ECUs), data loggers, and other sensors, providing a comprehensive view of vehicle performance. The CAN bus connectivity enables communication with modern vehicle architectures, while the serial ports offer compatibility with older systems.
The integrated lap beacon receiver simplifies lap timing, providing accurate and consistent data for performance analysis. This feature, combined with the extensive data logging capabilities, makes the Omega ICD an invaluable tool for drivers, engineers, and team managers.
The device supports firmware updates, allowing for future enhancements and bug fixes. This ensures that the Omega ICD remains up-to-date with the latest features and functionalities.
The Omega ICD is designed for durability and ease of maintenance. Its robust aluminium construction and sealed enclosure protect the internal components from environmental damage.
For installation, the unit should be protected against severe vibrations by mounting using supplied AV mounting kit. It's important to ensure the unit is not fouling other structures which may experience severe vibrations. The unit should be positioned in an area with an ambient temperature of less than 50°C or with sufficient cooling air flow to prevent overheating. The unit should be mounted away from sources of electrical interference. Finally, ensure the unit is mounted in a position where the unit will not come into contact with water, and do not ground the case, use the power pins provided.
The device is equipped with a rechargeable battery (Lithium Vanadium Pentoxide). The equipment may be returned to Cosworth Electronics for a replacement battery. The battery is user-removable, and the manual provides instructions for removal. To remove the battery for recycling, users should remove the case cover(s), remove the printed circuit boards from the case, and then remove the battery from the printed circuit board. Disposal of the battery should be in accordance with regulations in force.
The Omega ICD is designed to be a long-lasting device, with minimal maintenance requirements. Regular cleaning of the display screen with a soft cloth is recommended to maintain optimal visibility. The connectors should be inspected periodically for any signs of wear or corrosion.
In the event of a malfunction, Cosworth Electronics provides support and service for the Omega ICD. The device is designed for easy repair, with modular components that can be replaced if necessary. The manual includes detailed information on troubleshooting and repair procedures.
The Omega ICD complies with various environmental and safety regulations, including RoHS and WEEE directives. This ensures that the device is manufactured and disposed of in an environmentally responsible manner.
Loading...