600568 Rel-0006
Coverlink™ Wireless Control
Troubleshoot Guide
Qualied service personnel only
PROBLEM SOLUTION
Auto-shutoff Verication
Cover system does not operate or
operates intermittently.
Step 1. Check for secure wiring connections at the Circuit Breaker,
Auto Shutoff Board, Receiver Board, and Motor.
Check that the Antenna wire is secure and not damaged.
All wiring is good, go to step 2.
Step 2. Reboot the receiver:
Turn the system power off to the receiver and auto-shutoff
board, leave it off for 30 seconds, then turn the system power
back on.
Step 3. Use the CoverLink override buttons on the receiver
(Uncover & Cover).
If the buttons work, go to Troubleshoot CoverLink.
If the buttons do not work, go to step 3
Step 4. Disconnect the receiver from the auto-shutoff. Short the key
switch wires together (Black to Yellow should cover the pool &
Black to Green should uncover the pool).
If the Auto-shutoff works, go to Troubleshoot CoverLink.
If the Auto-shutoff does not work, see Document 600356 Adjusting
the AMP Limiter and LED Function of the Auto-shutoff.
6 of 7
Verify that the Auto-shutoff board is working properly prior to troubleshooting the CoverLink system.
©Cover-Pools Inc.
Electrical Details 7:24
600568 Rel-0006