Covidien Nellcor PM10N Service Manual

Covidien Nellcor PM10N
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Service Manual
Nellcor
Portable SpO
2
Patient Monitoring System
TM

Table of Contents

Other manuals for Covidien Nellcor PM10N

Question and Answer IconNeed help?

Do you have a question about the Covidien Nellcor PM10N and is the answer not in the manual?

Covidien Nellcor PM10N Specifications

General IconGeneral
Product TypePulse Oximeter
BrandCovidien Nellcor
ModelPM10N
Monitoring ParametersSpO2, Pulse Rate
DisplayColor LCD
Battery LifeUp to 8 hours
Compatible ProbesNellcor SpO2 sensors
Pulse Rate Accuracy±3 bpm
Operating Temperature5°C to 40°C (41°F to 104°F)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Power SourceAC Power, Battery
ConnectivityUSB, Bluetooth
SpO2 Range0% to 100%
SpO2 Accuracy±2% (70% to 100% SpO2)
Pulse Rate Range20 to 250 bpm

Summary

Introduction to Nellcor SpO2 Monitoring System Service

Overview of the Service Manual

Provides an overview of the service manual's scope for the Nellcor monitoring system.

Safety Information for Nellcor System

Understanding Safety Symbols

Defines safety symbols used in the manual and their meanings.

Explosion, Shock, and Toxicity Hazards

Details hazards related to explosion, electric shock, and toxic materials.

Service Procedures and Precautions

System Operation and Service Guidelines

Patient Monitoring Safety Considerations

Monitoring System Readings and Accuracy

Sensors, Cables, and Accessories Safety

Electromagnetic Interference Precautions

Connections with Other Equipment Safety

Monitoring System Storage, Transport, and Disposal

Obtaining Technical Assistance

Contacting Technical Services

Information on contacting Covidien for technical support and assistance.

Related Documents for Nellcor System

Lists related manuals and documentation for the monitoring system.

Warranty Information for Nellcor System

Service Menu Options for Nellcor Monitor

Overview of Service Menu

Introduces the Service Menu settings and access requirements.

Safety Reminders for Service Menu Use

Provides safety precautions related to product performance and accessory use.

Service Menu Overview and Structure

Details the structure and accessibility of the Service Menu.

Power On Settings Configuration

Configures how the monitoring system starts up (defaults, last settings).

Permission to Mute Audible Alarms

Allows or disallows users to mute audible alarms for SpO2 and pulse rate.

Alarm Silence Duration Settings

Sets the time duration for which audible alarms remain silent.

Power Saving Settings for Battery Life

Options to conserve battery life, including screen saver and auto power off.

Battery Type Selection for Optimization

Selects the battery type (Lithium or Alkaline) for power optimization.

Date and Time Settings Configuration

Configures the date format and time for the monitoring system.

Communication Settings for Data Transfer

Sets serial connectivity parameters for data transfer.

Alarm Priority Settings Adjustment

Adjusts alarm priorities for various sensor-related and vital sign alarms.

Language Selection for Menu Display

Selects the display language for menu items.

Dynamic Password Management

Manages passwords for switching between different operating modes.

Enable PCSync Mode Utility

Enables or disables the PCSync utility for testing and firmware upgrades.

About Monitor Information

Displays model name and software versions of the monitoring system.

Covidien Service Access Information

Information and access restrictions for Covidien service personnel only.

Data Management for Nellcor System

Overview of Data Management

Introduces accessing, transmitting, and downloading patient data and firmware upgrades.

External Data Communication Setup

Covers connecting the system to other devices for data transfer and compliance.

Monitoring History Download Procedure

Details the process of downloading patient monitoring history data.

Firmware Upgrade Process

Provides instructions and precautions for upgrading the system's firmware.

Modification and Testing of Nellcor System

Overview of Modification and Testing

Introduces performance verification tests after repairs or during maintenance.

Required Equipment for System Testing

Lists the necessary equipment for performing system tests.

System Performance Tests

Tests conducted to verify the monitoring system's performance parameters.

Power-On Self-Test (POST) Procedure

Describes the procedure to check the system's self-test upon startup.

Battery Status Verification

Explains how to verify the battery status and capacity indicators.

Patient Modes Verification

Guides on verifying selection and appearance of different patient modes.

Homecare Mode Verification

Provides steps to verify the functionality of Homecare Mode.

Sleep Study Mode Verification

Guides on verifying the selection and display of Sleep Study Mode.

Dynamic Passwords Configuration

Instructions for changing passwords to switch between care modes.

Date and Time Settings Verification

Details how to verify the accuracy of the system's date and time settings.

Operational and Functional Tests

Tests related to the system's operation and functional capabilities.

General Operation Tests

Covers basic operational checks and LED excitation tests.

Functional Tests with SRC-MAX

Guides on performing functional tests using the SRC-MAX oximetry tester.

BPM (PR) Test Procedure

Tests the monitoring system's response to BPM inputs from the SRC-MAX.

SpO2 Test Procedure

Verifies the monitoring system's response to SpO2 values from the SRC-MAX.

Modulation Level Test Procedure

Tests the system's performance with varying pulse modulation levels.

Light Level Test Procedure

Evaluates system response under different ambient light conditions.

Verification Check Sheets for Testing

Provides forms for recording test results of performance, operation, and functional tests.

Troubleshooting the Nellcor SpO2 Monitor

Overview of Troubleshooting

Introduces common problems and troubleshooting guidelines for the system.

Troubleshooting Guide and Categories

Lists potential problems and their corrective actions.

Error Conditions by Category and Resolution

Categorizes error conditions and provides solutions for power, NELL-1, and display issues.

System Error Codes Identification

Lists system error codes displayed on the LCD and their technical error conditions.

Return Instructions for Service

Provides instructions for returning the monitoring system for repair or service.

Repairing the Nellcor SpO2 Monitoring System

Overview of Repair Procedures

Introduces repair information, safety warnings, and major component parts.

Spare Parts and Accessories List

Lists available spare parts and accessories for ordering and replacement.

Required Tools for Repair

Lists the tools necessary for disassembling and repairing the monitoring system.

Battery Replacement Guide

Provides instructions for replacing the system's AA batteries.

Disassembly and Reassembly Procedures

Details the steps for disassembling and reassembling the monitoring system components.

Front and Rear Assembly Replacement

Details the procedure for replacing the front and rear assemblies.

NELL1SR Board Replacement

Steps for removing and replacing the NELL1SR board.

Main Board Replacement Procedure

Instructions for removing and replacing the main circuit board.

Coin Cell Battery Replacement

Procedure for replacing the coin cell battery on the main board.

LCD Replacement Procedure

Steps for removing and replacing the LCD screen.

PI Cable and Cable Housing Replacement

Procedure for removing and replacing the PI cable and housing assembly.

Related product manuals