Water Filtration System Performance Data Sheet
Model: AQUAMEGA 100
reduction of the substances listed below and NSF/ANSI 372 for lead free compliance. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
Substance concentration
Maximum Allowable
Product Water
Concentration
Percent reduction
(%)
Aesthetic Chlorine 2.00 ± 10% ≥50% Reduction 99.2%
Chloramine
3.00 ± 10% 0.5 99.2%
Turbidity
11 ± 1 NTU 0.5 NTU 99.09%
VOC*
3.00 ± 10% ≥95% Reduction 99.8%
Mercury
0.006 ± 10% 0.002 85.0%
Lead
0.15 ± 10% 0.01 99.8%
Cyst
Minimum 50 000 /L ≥99.95% Reduction 99.99%
As monochloramine (measured as Cl /L)
While testing was performed under standard laboratory conditions, actual performance may vary.
General Operating Information:
Rated Capacity
300 gallon (For VOC, Lead, Mercury, Cyst and Turbidity reduction)
500 gallon (For Aesthetic Chlorine and Chloramine reduction)
Min-Max operating pressure:
20 ~ 120 psi (138 KPa ~ 827 KPa)
Min-Max feed water temperature:
41 ºF ~ 95 ºF (5 ºC ~ 35 ºC)
Rated Service Flow
0.4 gpm
*
Chlorine reduction based on surrogate chloramine reduction.
• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
•
responsibility, and parts and service availability.
• For parts and service availability, please contact your local dealer or Coway.
•
•
may be shortened in case it is used in an area of poor water quality.
Type Usable period
A-1 Sediment Filter 6 months
A-2 PreCarbon Filter 6 months
A-3 Post Carbon Filter 6 months