Water Filtration System Performance Data Sheet
Model: CHP-6310L(MY)
This system has been tested and certified by the Water Quality Association according to NSF/ANSI 42, 53, 58.
The concentration of the indicated substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specied in NSF/ANSI 42, 53, 58.
Substance
IInuent challengeConcentration
(mg/L unless specied)
Maximum permissible Product water
Concentration
(mg/L unless specied)
Percent Reduction
(%)
Arsenic (Pentavalent) 0.050 ± 10% 0.01 97.8
Barium 10.0 ± 10% 2 97.2
Radim 226/228 25 pCi/L 5 pCi/L 80
Cadmium 0.03 ± 10% 0.005 98.2
Chromium (Hexavalent) 0.3 ± 10% 0.1 98.6
Chromium (Trivalent) 0.3 ± 10% 0.1 99.4
Copper 3.0 ± 10% 1.3 98.1
Lead 0.15 ± 10% 0.01 99.1
Selenium 0.10 ± 10% 0.05 98.3
TDS 750 ± 40 187 89.9
Aesthetic Chlorine 2.0 ± 10% ≥ 50% Reduction 72.8
VOC* 0.300 ± 10% ≥ 95% Reduction 99.4
Cyst Minimum 50 000/L 0.9995 99.99
While testing was performed under standard laboratory conditions, actual performance may vary.
General Operating Information:
Daily production Rate 152.6 L/day
Rated Capacity
680 L (for VOC)
11 000 L (for Aesthetic Chlorine)
Min-Max operating pressure: 1.4 MPa ~ 0.83 MPa
Min-Max operating temperature: 5 ºC ~ 35 ºC
Rated Service Flow 0.26 L/min
Electrical Requirement Refer to rating plate
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.
Systems certied for cyst reduction may be used on disinfected waters that may contain lterable cysts.
The estimated replacement time of lter, which is a consumable part, is not an indication of quality guarantee
period, but it means the ideal time of lter replacement. Accordingly, the estimated time of lter replacement
may be shortened in case it is used in an area of poor water quality.
The ltration device installation shall comply with applicable state and local regulations.
WATER FLOW DIAGRAM / PERFORMANCE DATA SHEET | CHP/CP-6310L
Others

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Coway CHP/CP-6310L and is the answer not in the manual?

Coway CHP/CP-6310L Specifications

General IconGeneral
BrandCoway
ModelCHP/CP-6310L
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals