EasyManua.ls Logo

COZY CDV305D - User Manual

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
WARNING: If the information in these instructions is not
followed exactly, a re or explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other ammable vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
Open all windows.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone or
cell phone in your building.
Extinguish any open ame.
Immediately call your gas supplier from a neighbors phone.
Follow the gas suppliers instructions.
If you cannot reach the gas supplier, call the re department.
Installation and service must be performed by a qualied
installer, service agency or the gas supplier.
14,000 BTU/hr.
DIRECT VENT GRAVITY
WALL FURNACE
WARNING:This Direct-Vent furnace is approved for aftermarket
manufactured home installations (once the manufactured home is
sold, installed and stationary) unless prohibited by local codes.
Not for manufactured home manufacturer (factory) installation. Do
not install any of these furnaces (natural or propane gas)in trailers
or recreational vehicles.
WARNING: This product can expose you to chemicals
including epichlorohydrin which is known to the State of California
to cause cancer and birth defects and/or other reproductive harm.
For information go to www.p65warnings.ca.gov
WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause injury or property damage.
Refer to this manual. For assistance or for additional information
consult a qualied installer or, service agency.
MODEL NUMBERS (natural gas)
CDV142E / CDV222E / CDV302E
MODEL NUMBERS (propane gas)
CDV141E / CDV221E / CDV301E
DISCONTINUED MODEL NUMBERS:
CDV155D / CDV156D / CDV255D
CDV256D / CDV305D / CDV306D
SAVE THIS MANUAL FOR FUTURE REFERENCE.
READ THIS OWNER’S MANUAL CAREFULLY BEFORE YOU
INSTALL YOUR NEW COZY WALL FURNACE.
250 West Laurel Street, Colton CA 92324 • www.cozyheaters.com • 1-888-444-1212
22,000 & 30,000 BTU/hr.
OWNERS MANUAL
INSTALLATION INSTRUCTIONS
VISITE NUESTRA PÁGINA WEB PARA LA VERSIÓN EN ESPAÑOL DE ESTE MANUAL
https://www.cozyheaters.com/products

Other manuals for COZY CDV305D

Questions and Answers

  • M
    Melinda BlackAug 14, 2025
    What to do if my COZY CDV305D Furnace won't ignite?
    • J
      jessica01Aug 15, 2025
      If your COZY Furnace fails to ignite, possible causes include the main gas being off (open all manual gas valves), the thermostat not being set high enough (set it to a higher temperature), a clogged burner orifice (clean it, but do not enlarge it), incorrect or defective thermostat wiring (check the wiring, jump across the thermostat terminals at the valve; if the valve opens, re-check the wires and replace the thermostat if needed), or a defective valve (replace the valve).
  • Y
    ybrooksAug 18, 2025
    How to check incorrect gas input in COZY CDV305D Furnace?
    • P
      Patrick WilliamsAug 18, 2025
      Incorrect gas input in your COZY Furnace may be due to the gas input not being checked (re-check the gas input) or a clogged orifice (clean the orifice with a smooth wood toothpick, do not enlarge).
  • E
    Elizabeth LucasAug 21, 2025
    Why is my COZY CDV305D burner not turning off?
    • D
      David ZamoraAug 22, 2025
      If your COZY Furnace burner won’t turn off, it could be due to a defective or damaged thermostat wire or thermostat (remove the wire from the valve terminal; if the valve goes off, replace the wire or thermostat), the thermostat location (follow the installation instructions and check the location), a defective or sticking valve (clean or replace the valve), or excessive gas pressure (contact the utility supplying the gas).
  • P
    pottermargaretAug 25, 2025
    What to do if my COZY CDV305D pilot and main burner go out during normal operation?
    • D
      Dennis AllisonAug 26, 2025
      If the pilot and main burner of your COZY Furnace go out during normal operation, it may be due to a weak powerpile or thermocouple (check millivoltage and replace if low), input being too high (check input rate), the cover around the pilot lighter hole not being airtight (tighten wing nuts securing the cover and sight glass; check and replace the gasket if needed), vent tubes not properly installed or sealed (follow the instructions, check both exhaust and air intake tubes and vent cap; be sure all gaskets are in place and properly sealed; use only tubes and vent cap supplied, do not alter vent tubes or cap), or incorrect vent tubes (replace with correct tubes).
  • A
    Anna CampbellAug 28, 2025
    Why is my COZY Furnace not producing enough heat?
    • T
      Teresa CarrilloAug 28, 2025
      If your COZY Furnace isn't producing enough heat, the furnace might be undersized (have the heat loss calculated and compare it to the furnace output; your gas company can supply you with this information; if the furnace is undersized, replace it with the correct size unit), the thermostat might be set too low (raise the temperature setting), or the supply pressure might be incorrect (check the supply pressure).
  • J
    Joshua BowmanAug 31, 2025
    Why is my COZY CDV305D flame too large?
    • K
      Kathleen MccoyAug 31, 2025
      If the flame in your COZY Furnace is too large, it could be due to a defective operator section of the valve (replace the valve), a burner orifice that is too large (check with the local gas company for the proper orifice size and replace it), or if the furnace is installed above 2,000 ft (see burner orifice section, Page 13).
  • A
    Andrew HolmesSep 3, 2025
    What causes yellow burner flame in COZY Furnace?
    • C
      Cheryl CantuSep 4, 2025
      A yellow burner flame in your COZY Furnace can be caused by clogged burner ports (remove the main burner and check for obstructions in the throat, ports, and orifices; clean, but do not enlarge ports or orifices) or an obstruction around the vent cap (make sure the area around the vent cap is clear, and be sure the vent system is sealed).
  • M
    Matthew AyalaSep 7, 2025
    Why does my COZY Furnace have delayed ignition?
    • M
      Maxwell BakerSep 7, 2025
      Delayed ignition in your COZY Furnace can occur if the pilot flame is too small (adjust the pilot flame), burner ports are clogged at the pilot (clean burner ports, but do not enlarge them), gas pressure is low (check gas supply pressure), or the pilot decreases in size when the main burners come on (the supply piping is too small; consult the local gas company or a competent installer).
  • D
    Denise MullinsSep 12, 2025
    What causes too much heat from COZY CDV305D?
    • M
      Marc SmithSep 12, 2025
      If your COZY Furnace is producing too much heat, it might be because the thermostat is set too high (lower the temperature setting) or the combination control valve is stuck open (replace the combination control valve).

Summary

WARRANTY

Limited Warranties

Details the one-year and extended limited warranties for the furnace, covering parts and potential issues.

SAFETY RULES

General Safety Precautions

Essential safety guidelines for installation, operation, and maintenance of the furnace to prevent injury or damage.

INTRODUCTION

Carbon Monoxide Safety

Critical steps to prevent carbon monoxide poisoning related to venting procedures.

INSTALLING YOUR FURNACE

Locating the Wall Furnace

Guidance on selecting an appropriate installation location for the furnace, considering clearances and environmental factors.

Gas Supply and Piping

Gas Supply Requirements

Details on minimum and maximum gas supply pressures for natural and propane gas.

Gas Piping and Connections

Instructions for proper gas piping layout, connections, and safety checks, including conversion kits.

Checking the Gas Piping

Procedures for testing gas piping for leaks to ensure safety and proper operation.

INSTALLATIONS IN THE STATE OF MASSACHUSETTS

OPERATING YOUR FURNACE

Lighting the Pilot

Detailed instructions for safely lighting the pilot light using the manual spark igniter or a match.

Start-Up and Adjustment Procedures

Covers initial furnace start-up, gas input checks, and pilot/burner flame adjustments.

CARING FOR YOUR FURNACE

BLOWER ACCESSORY 2302 & 2303

TROUBLESHOOTING YOUR FURNACE

Common Issues and Corrective Actions

Details common furnace problems, their potential causes, and recommended solutions for technicians.