23
Frequencies tested 121.5 Mhz. & 406.0 to 406.1 Mhz.
Frequency resolution +/- 100 cycles
Frequency stability 2 parts per million 0 deg. F to 120 deg. F
3 red/green LEDs, fail/pass indicators
80 character message display, 4 lines, 20 characters per line
Inactivity auto shut off (15 minutes)
Continuous field strength mode (121.5 Mhz. only)
Temperature limits 0 deg. F to 120 deg. F
Battery requirement 8 AA batteries
Battery life
Lithium 12 hours continuous, approximately 50 tests @ 15 minutes a test
Alkaline 3.5 hours continuous, approximately 14 tests @ 15 minutes a test
Self- test
Battery level Warning message and disable when below accuracy level
Temperature Warning message and disable until temperature within limits
Minimum signal levels
Size 9 3/4“ Wide, 6 1/8” High, 2 1/2” deep
Weight 1.6 Lbs. Includes Lithium batteries