INSTALLATION GUIDE
HOW TO POSITION AND PROGRAM THE FLASH PROGRAMMER 2S
PRODUCT FUNCTIONS
Centralised programming for two heating zones
using two temperature modes:
- Comfort temperature
- Reduced temperature
Manual override function in comfort and reduced mode for each room.
PRINCIPLE OF OPERATION
Convectors equipped with a suitable electromechanical thermostat:
Reduced temperature obtained by supplying a resistance, which overrides the sensing element of the
thermostat.
Convectors equipped with a suitable electronic thermostat:
Reduced temperature achieved by delivering an alternating signal (coding adopted by all designers since
January 1994)
TECHNICAL CHARACTERISTICS
Time switch: Electronic clock with day and week programs.
Power backup: By lithium battery, backup guarantee for a total of 3 years minimum against mains failure
(battery life: 10 years)
Program increments: 1 minute
Number of zones: 2
Total maximum current rating: 0.5A
Dimensions: 167mm x 84mm x 44mm
INSTALLATION
1 Unscrew the time switch fixing
screw
2 Separate the base plate from
the casing using a screwdriver
3 Surface-Mounted base with 2off
screw fixings Ø3mm maximum
4 Electrical connections (see page 2)
IMPORTANT Insert the flying
lead from the display panel into the
socket on the circuit board as shown
5 Put outer casing back on
6 Put back in and tighten the
time switch fixing screw
1
Question and Answer IconNeed help?

Do you have a question about the Creda Flash 2S and is the answer not in the manual?

Creda Flash 2S Specifications

General IconGeneral
BrandCreda
ModelFlash 2S
CategoryThermostat
LanguageEnglish

Summary

Product Functions

Principle of Operation

Technical Characteristics

Installation

Setting the Time

Programming

Programming Zone 1 C1

Guides programming for Zone 1, setting comfort and reduced times for weekdays.

Programming Zone 2 C2

Guides programming for Zone 2, mirroring Zone 1 setup for different zones.

Auto Mode

Checking Switching Times

Modifying or Cancelling Switching Times

Modifying Switching Times

Details on changing existing programmed times for comfort or reduced modes.

Deletion of the Affect of a Switching Time on Certain Days

Explains how to remove programmed times from specific days of the week.

Adding Days to a Switching Time

Instructions for extending programmed times to include additional days.

Permanently Overriding Timer Mode

Temporarily Overriding Timer Mode (Holidays etc)