Regulators repair and maintenance
Regulators repair and maintenance
1
1
st
st
stage MC5:
stage MC5:
assembling phases DIN
assembling phases DIN
Using the threaded
bar, tighten the 1st
stage body in a
vice. Tighten the
DIN filter body with
a dynamometric
spanner, supplied
with a 22 mm
(8,66”) hexagonal
insert. Apply a
force of 30 N x m.