9000 operation and maintenance instructions
IMPORTANT!!!!!
1. Read instructions thoroughly before operating!!
2. After shipping the unit via courier or after rough handling such as falling off a shelf open cabinet by
following step 1 of the cleaning instructions. Check to make sure the center screen of the generator plate has
not moved out of place. Once this has been checked the plate rack may be reinstalled and the unit is ready
for use.
CAUTION, THIS OZONE GENERATOR OPERATES AT 4000-5000 VOLTS AC
DISCONNECT POWER BEFORE OPENING TO SERVICE
SPECIFICATIONS FOR 3600 SERIES ozone generator
Maximum output 9000:(2000mg/hr up gradable to 9000mg/hr)
Fan (rated cfm) 105 cfm
Filter 1 Cleanable foam filters
Cabinet material PVC outer cabinet with stainless steel inner chassis
Generation method Corona discharge
Weight and size 9000:11.7lb 21" long x 5 wide x 6 5/8 height (including handle)
INTRODUCTION
This line of ozone generators are designed for various uses at varying output levels. This ozone generator can be used for
many uses such as deodorizing cars homes as well as oxidizing many organic contaminants.
WARRANTY
The 3600-9000 is warranted against defects in materials and workmanship for a period of 6 years from date of purchase.
Liability is limited to parts and labor only. Shipping is the sole responsibility of the customer. CAMI is not liable for damage
caused by shipping, misuse, neglect or lack of regular maintenance.
LIABILITY
CAMI assumes no responsibility for any damage done to items from the use or miss use of any product sold or manufactured
by CAMI. It is the customers responsibility to test materials prior to use and to ensure that the procedure and installation
technique they are using is correct for the application.
HEALTH AND SAFETY
Ozone can be an irritant and a powerful oxidizing agent. As with most all products, ozone is dangerous only when used
improperly, as such it is important to follow safe usage guide lines.
*When doing a shock treatment, no people plants or pets/animals may be in the room when the unit is running.*
The room should not be re entered until all ozone has been depleted unless proper breathing respirators are used.
MAINTENANCE FREQUENCY
Under heavy duty use or severely polluted areas, The ozone generator should be inspected and cleaned if necessary every 2
to 3 weeks for fine dust or oily residue collecting on generator surfaces or plates. Light duty use requires cleaning every 2 to
6 months depending on the severity of pollution and the humidity level of the feed air. In dirty and humid conditions cleaning
can be as often as 2-4 weeks.
DESCRIPTION OF OZONE GENERATOR
These ozone generators produce ozone by corona discharge, converting normal oxygen to ozone gas which is a very strong
oxidizing agent used to destroy odors and other organic contaminants. The model 3600 comes from the factory with 1 plate,
producing up to 1000mg/hr, and can be up graded by adding as many as 4 additional plates to a max of 3600mg/hr. The
model 9000 comes from the factory with 2 plate, producing up to 2000mg/hr, and can be up graded by adding as many as 8
additional plates to a max of 9000mg/hr.
PLACEMENT OF UNIT
This ozone generator is designed as a portable commercial deodorizing device. It uses 120VAC for North America, and 220-
240VAC for European countries etc. European models come with an IEC connector and it is up to the customer to supply the
proper cord (this can be acquired at any computer shop).
Please note the following points when placing the unit.
-Place on a flat solid surface such as a table or shelf. Do not place on rug flooring to reduce dust entering the unit
-Do not place in an area where the unit could be splashed with water, moisture or in an area that it could get flooded with
water.
-Ensure that the unit gets proper fresh air flow. Do not obstruct the incoming or outgoing air from the unit.
-DO NOT USE IN VICINITY OF COMBUSTIBLE GASSES!!
-Humidity levels higher than 75% should be avoided as it will cause the unit to wear excessively fast and will require cleaning
much more often.
-If used in temperatures below freezing, ensure that condensation inside the unit does not occur.
-Set the unit in an area where it will provide the best ozone distribution.
-The use of circulation fan will greatly increase the efficiency of the treatment.
-If the ozone generator being used is large enough to treat the whole house, the air handling system can be used to distribute
the ozone, just point the ozone generator into the return air duct.
Question and Answer IconNeed help?

Do you have a question about the Crystal air 9000 and is the answer not in the manual?

Crystal air 9000 Specifications

General IconGeneral
BrandCrystal air
Model9000
CategoryAir Cleaner
LanguageEnglish

Summary

Specifications for 3600 Series Ozone Generator

Health and Safety

Placement of Unit

Setting of Machine

Setting Ozone Level (occupied areas)

Guidance on adjusting the ozone output level for occupied areas to achieve optimal deodorization.

Trouble Shooting

Fan works but no ozone

Steps to diagnose and resolve issues where the fan operates but no ozone is produced.

No fan and no ozone

Troubleshooting steps for when both the fan and ozone production are not functioning.

Generator sounds erratic, crackling, or like it is arcing, popping, etc.

Guidance on addressing unusual sounds from the generator, such as arcing or popping.

6 Year International Warranty Statement