CSI Controls RK Series Specifications

General IconGeneral
BrandCSI Controls
ModelRK Series
CategoryRecording Equipment
LanguageEnglish

Summary

About the RK Series Float Systems

Float System Installation Instructions

Step 1: Installing the Floats

Details on how to install floats using tie wraps or mounting brackets.

Float System Installation Instructions

Step 2: Installing the Controller

Steps for mounting and wiring the control panel.

Float System Installation Instructions

Typical Float System Installation Diagram

Visual guide showing float placement and connections in a tank.

Understanding the Float System

Subdoor Control Center

Overview of the control panel's subdoor components and indicators.

Float Indication Status Lights

Explains the meaning and function of float status LEDs.

Float System Features

Hand Run Buttons

Details on manual operation pushbuttons and their safety function.

Blown Fuse Indicators

Explanation of indicators for blown fuses and power status.

Audible Alarm Circuitry

Description of the audible alarm and 'Touch-To-Silence' feature.

Float System Features

Redundant Off Float

Describes the 'Redundant Off Float' option for preventing dry running.

Auxiliary Alarm Contact

Details the 'Auxiliary Alarm Contact' for remote alarm notification.

RK "E Series"

Introduces the economical 'E Series' model and its features.

DDCs and DIBS

Explains the availability of Digital Display Centers and Interface Boards.

Understanding the "E Series" Float System

Subdoor Control Center

Details the subdoor control center for the 'E Series' model.

Hand-Off-Auto Switch

Explains the function of the Hand-Off-Auto switch on the subdoor.

Digital Display Center (DDC)

Installation

Instructions for installing the DDC module onto the control panel.

Display Menu

Explains the 'Display Menu' fields like Elapsed Time and Cycle Counter.

Digital Display Center (DDC)

User Settings Menu

Accessing and navigating DDC User Settings, Level Control, and Time Dosing menus.

Level Control Options Menu

Configuration options for pump lead selection and cycle counter reset.

Digital Display Center (DDC)

Time Dosing Options Menu

Settings for pump enable/disable times and alarm/override functions.

High Level Time Delay (HLtd)

Configuration for delaying the High Level Alarm based on time.

Digital Display Center (DDC)

DDC Flow Chart

Visual representation of the DDC menu navigation and options.

Digital Interface Board (DIB)

Installation

Instructions for installing the DIB module onto the control panel.

Menu Navigation

How to navigate through DIB menus and fields.

Editing Fields

How to edit DIB settings and values.

Digital Interface Board (DIB)

Display Menu

Explains DIB display fields like Elapsed Time, Cycle Count, and Active Alarm.

User Settings Menu

Accessing and navigating DIB User Settings, Level Control, Time Dosing, Telemetry, and Alarm History menus.

Digital Interface Board (DIB)

Level Cntrl Menu

Configuration for Lead Pump Set and resetting cycle counters or elapsed time.

Digital Interface Board (DIB)

Time Dosing Options Menu

Settings for pump enable/disable times and override times for Time Dose versions.

Digital Interface Board (DIB)

Time Dosing Options Menu (Continued)

Details on Alarm/Override settings and High Level Delay for Time Dosing.

Number of Fields

Setting Time Dosing operation for 'One Field' or 'Two Fields'.

Digital Interface Board (DIB)

Alarm History Menu

Displays the last three alarms that have occurred.

Auxiliary Inputs

Information on the three auxiliary inputs and their ratings.

Flash Codes

Explains different flash rates of the alarm light for specific errors.

Digital Interface Board (DIB)

Subdoor Control Center

Flow chart detailing navigation between Display and Settings menus on the DIB.

Float System Troubleshooting

Panel Power Lights Not On

Troubleshooting steps for when panel power lights are not illuminated.

Fuse Light On

Guidance for issues related to blown fuses and indicator lights.

Float Indicator Lights Flashing

Steps to resolve flashing float indicator lights and potential float issues.

Float System Troubleshooting

Pump(s) Will Not Run in Automatic

Steps to troubleshoot pumps not running in automatic mode.

High Level Alarm Activated

Troubleshooting steps for when the High Level Alarm is activated.

Enclosure Dimensions

Field Wiring Connections

Terminal Strip With All Available Options

Details the terminal strip layout and available connection options.

Determining Your RK Model Number

Guide to identifying the RK model number based on type, voltage, and options.

Float System Specifications