TECHNICAL DATA:
Power Six “AA” (11⁄2 volt) batteries
Battery life 100 hours of intermittent operation (alkaline
batteries) Magnification
Output Powerful magnetic speaker with molded cover
to protect from direct contact.
LCD Display Numeric digital, analog Bar-graph, power line
indicator and low battery indicator feature
Weight Approximately 2.5 lbs. with batteries
Operating temperature 0°F to 120°F (-18°C to 49°C)
Length 42 3⁄4 inches (108.6 cm)
Construction High-impact water resistant plastic, epoxy
painted. Aluminum sensor tube waterproof to
just under the plastic case.
Nominal Sensor 20 inches (50.8 cm)
Specifications subject to change without notice.
BATTERY REPLACEMENT
(1) Switch off the device using the main switch
(2) Remove the battery cover
(3) Insert the batteries as shown in the illustration(fig. 3)
(4) Close the battery compartment lid and click it home
OPERATION
Switch on the device
Check battery levels:
Battery symbol
in the display shows: 3 fields: Battery full
2 fields: Battery operable
1 field: Battery almost empty
0 fields: Battery empty