DISPOSAL
The preferred method of disposal is through recycling. For
environmental reasons, do not dispose of the device in the
household waste. Dispose of it at a suitable local collecon
or recycling point in accordance with EC Direcve– WEEE
(Waste Electrical and Electronic Equipment). If you have any
quesons, please contact the local authories responsible
for waste disposal.
The box and user manual are card / paper and fully recyclable.
WARRANTY
Under normal use this product is guaranteed for 2 years
aer its original purchase date against manufacturing
defects in materials or workmanship. This warranty extends
only to the original purchaser. If the product should become
faulty within the warranty period, contact CurrentBody.
CURRENTBODY reserves the right to repair a defecve
product.
CURRENTBODY reserves the right to replace a defecve
product with the most compable product currently
available.
This warranty does not cover damage caused by the
following:
- Accident, misuse, abuse or alteraon
- Servicing by unauthorised persons
- Connecon to incorrect power sources
- Use with unauthorised accessories
CurrentBody shall not be responsible for any incidental,
special or consequenal damages resulng from the use
of this product. All implied warranes, including but not
limited to implied warranes of tness and merchantability
are limited in duraon to two years from date of original
purchase. This warranty gives you specic legal rights,
and you may also have other rights that vary from country
to country. Some countries do not allow the exclusion
or limitaon of incidental or consequenal damages, or
limitaons on how long an implied warranty lasts, so some
of the above limitaons and exclusions may not apply to
you. This warranty is given in lieu of all other warranes,
wrien or oral, whether expressed by armaon,
promise, descripon, drawing, model or sample. Any and
all warranes other than this one, whether expressed or
implied, including implied warranes of merchantability and
tness for a parcular purpose are hereby disclaimed. If
the product is defecve within the warranty period please
contact CurrentBody.
DEVICE SPECIFICATION
The RF handheld device is powered by bipolar RF at
6±0.5 Watt
Frequency: 1±0.05 [MHz}.
Selectable output

3 levels.
Temperature
sensors:
RF heating is automatically
deactivated when skin
temperature reaches
43ºC/109ºF The heating is
reactivated when temperature
decreases.
Treatment area: ~2.2cm
2
/ 0.34in
2

supply:
Input 100-240VAC, 50-60Hz,
Output 9VDC, 1.5A
Device size and

96g, 145mm x 45mm x 42mm
3.4oz, 5.7in x 1.7in x 1.7in
STORAGE INSTRUCTIONS
STORAGE AND TRANSPORTATION CONDITIONS
Temperature:
-25ºC to 70ºC
(-13ºF to 158ºF)
Humidity: 10% to 90% RH at 55ºC/131ºF
Pressure: Non-condensing
OPERATIONAL CONDITIONS
Temperature:
5ºC to 43ºC
(43ºF to 109ºF)
Humidity: 20% tp 80% RH
Pressure: 3,000m.