Curtis 3140 Manual – Nov. 2017
5 — SPECIFICATIONS
pg. 15
Table 4 Specications continued
EMC SPECIFICATIONS
Emissions (Broadband & Narrowband):
Designed to meet UN ECE/324 Addendum 9 Regulation 10 Revision 4 (6 March
2012) for an Electrical/electronic sub-assembly (ESA).
Immunity:
ESD:
Designed to meet IEC 61000-4-2: Test level IV (8 kV contact discharge or 15
kV air discharge) according to ISO 10605:2001, Table B.1.
Radiated Imunity:
Designed to meet 30 V/m (20MHz to 1 GHz) when tested per ISO 11452–2,
Absorber-Lined Chamber (single sample).
Conducted Immunity:
Designed to meet IEC 61000-4-4: Test level 4 (4 kV peak, 2.5 kHz repetition
rate).
REGULATORY APPROVALS
UL: UL recognition to UL 583
CE:
The product complies with the requirements of the EMC Standards and RoHS
directive 2011/65/EU (RoHS 2).
The product conforms to the following
product specifications and regulations:
EMC: Radiated Emissions: UN ECE/324;
Radiated Immunity: ISO 11451-1 and ISO 11451-2, using the RF levels dened
in BS EN 13309:2010;
Electrical Transient Conduction: IEC 61000-4-4: Test level 4
(4 kV peak, 2.5 kHz repetition rate);
ESD: ISO 10605: 2001.
RoHS: RoHS directive 2011/65/EU (RoHS 2).