Adjust and Function Specification
200%
100%
200
100
20%
0V
4mA
20
10V
20mA
Analog
Setting
Signal
Note: If the maximum frequency ( FH ) exceeds more than 120Hz, gain setting of larger
than 100% is ignored and fixed at 100% and input data of Code 37 will not be
changed.
§Cd38 Analog output calibration (Settable range 90-110)
Set the ratio of frequency graduation calibration
then Cd38=99 99% of initial factory
Cd38=101 101% of initial factory
Set Cd54 to select analog output
§Code No.39 Frequency command bias (Settable range 0-250)
External analog frequency command bias setting
Frequency Output %
Settable Range
0V
Frequency Command
10V
§Cd40, 41, 42, 43 Multi-speed setting (Settable range 0.5-240)
This function has 8 kinds of speed operation
Use external terminal FR (or RR) accommodate 3, 4, 5 to select different
speeds. Refer to the following table: