Adjust and Function Specification
§ Cd84 Series communication broadcasting function setting settable range 0-3
This function can’t be modified during revolution
When setting communication, wither active group broadcasting (MODBUS Function
241~255) or global broadcasting (MODBUS Function 0) function.
Cd84=0 Active both group and global broadcasting.
Cd84=1 De-active group broadcasting, active global broadcasting.
Cd84=2 Active group broadcasting, de-active global broadcasting.
Cd84=3 De-active both group and global broadcasting.
§ Cd86 RS485 port utility setting (setting range 0-1)
The function cannot be modified during revolution
Selection of utility of 2 sets RS485 series communication interface.
Cd86=0 Only use RS422 or A set RS485 (Modbus protocol).
Cd86=1 Use A set for Remote Keypad, B set RS485 (Modbus protocol).
Cd86=2 Only use A set for Remote Keypad.
Caution:
1. When using B set RS485 series communication interface, J13 at PCB C16D115
must be shorted and adjust J11 to proper position.
2. When using B set RS485, Vout terminal will be disable.
3. Detail information refers to section at Serial Communications User Manual.