73
Adjust and Function Specification
§CE00,01,02,03 Failure record
Record cause of failure, in order to solve failure.
Note:1.Cannot record failure Err, Ero, Erc.
2.Only memorize 4 records.
3.Cannot record inverter stopped by low voltage.
4.Read only Cd00,01,02,03 or delete all (Code 36), cannot put in failure record by
operator.
§ CE11 - CE20 Multi-step function control frequency setting(settable range
0.5-240HZ)
Maximum 10 steps.
CE11 1
st
step speed setting
CE12 2
nd
step speed setting
CE13 3
rd
step speed setting
CE14 4
th
step speed setting
CE15 5
th
step speed setting
CE16 6
th
step speed setting
CE17 7
th
step speed setting
CE18 8
th
step speed setting
CE19 9
th
step speed setting
CE20 10
th
step speed setting
§ CE21 - CE36 Multi-step process control time setting(settable range 0 - 100Min)
Maximum 10 steps. End of entire procedure if time setting = 0.
CE21 1
st
step time setting
CE22 2
nd
step time setting
CE23 3
rd
step time setting
CE24 4
th
step time setting
CE25 5
th
step time setting
CE26 6
th
step time setting
CE27 7
th
step time setting
CE28 8
th
step time setting
CE29 9
th
step time setting
CE30 10
th
step time setting
§ CE37 1st frequency increase setting (setting range 0.0~10.0%)
(1st Bob up speed %)
Set the 1st frequency increase percentage. The setting is related with current working
speed of inverter.
When Inverter working under multi-step function mode(Cd01=7), and CE47=2, or 3,
Cd59=1, short terminal 5(UP) and COM, then the speed will be