Adjust and Function Specification
Bottom
freq.
Cd58
CE67
IN1
IN3
CE61
+
P
+
_
CE62
I
CE63
IN1
IN2
Output
limit
+
CE65
PI
Output
freq.
IN3
§ CE62 Proportion gain (settable range 0~10.0)
This parameter specifies proportional control and associated gain (P).
§ CE63 Integral gain (settable range 0.2~1000.0 sec)
This parameter specifies integral control (continual sum of the deviation) and
associated gain (I).
§ CE65 PI output limit setting (settable 0~100 %)
This parameter defines the percentage of output limit during the PID control.
§ CE67 PI control target value 1 (settable 0~100.0 %)
This parameter defines the percentage of target value.