page 54 - CYPRES 2 User’s Guide -
Standard settings for EXPERT CYPRES:
Cable length of control unit: ..... approx. 650 mm
Volume: ..................................... approx. 139 cm³
Weight: ...................................approx. 198 grams
Activation altitude: ........... approx. 750 - 130 feet
...................................... (approx. 225 - 40 meter)
Activation speed: .....approx. > 78 mph (35 m/s)
Standard settings for TANDEM CYPRES:
Cable length of control unit: ..... approx. 650 mm
Volume: ..................................... approx. 139 cm³
Weight: ...................................approx. 198 grams
Activation altitude: ......... approx. 1900 - 130 feet
...................................... (approx. 580 - 40 meter)
Activation speed: .....approx. > 78 mph (35 m/s)
Standard settings for STUDENT CYPRES:
Cable length of control unit: .... approx. 1000mm
Volume: ..................................... approx. 144 cm³
Weight: ...................................approx. 214 grams
Activation altitude: approx. 1000 / 750 - 130 feet
............................. (approx. 300 / 225 - 40 meter)
Activation speed: ......approx. > 29 mph (13 m/s)
Standard settings for SPEED CYPRES:
Cable length of control unit: ..... approx. 650 mm
Volume: ..................................... approx. 139 cm³
Weight: ...................................approx. 198 grams
Activation altitude: ........... approx. 750 - 330 feet
.................................... (approx. 225 - 100 meter)
Activation speed: ...approx. > 102 mph (46 m/s)
Standard settings for changeable MODE CYPRES:
Cable length of control unit: ..... approx. 650 mm
Volume: ..................................... approx. 139 cm³
Weight: ...................................approx. 198 grams
Activation altitude: .........according to set MODE
Activation speed: ...........according to set MODE
Activation altitude: All activation altitude references
in this User’s Guide are based on the standard setting
with no User-selectable activation altitude selection.
SAFETY INSTRUCTIONS
In the event of a cutaway, activation
will not occur until CYPRES has
veried all necessary para meters.