10
No. Name Range Factory Setting
o230* Alarm if there is an error as congured in o231-o239. e
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes 0.00
o231* Alarm for faulty safety edge. Time as in o230. 0 - 1 0
0 Constant signal
1 Active
o232* Alarm for uncritical error message in display 0 - 1 0
0 Constant signal
1 Active
o233* Alarm if stop circuit interrupted 0 - 1 0
0 Disabled
1 Constant signal
o234* Alarm if door open 0 - 1 0
0 Disabled
1 Constant signal
o235* Alarm if door is in mid position 0 - 1 0
0 Disabled
1 Constant signal
o236* Alarm if door is in closed position 0 - 1 0
0 Disabled
1 Constant signal
o237* Alarm if vehicle loop 1 is activated 0 - 1 0
0 Disabled
1 Constant signal
o238* Alarm if vehicle loop 2 is activated 0 - 1 0
0 Disabled
1 Constant signal
o239* Alarm if photocell interrupted 0 - 1 0
0 Disabled
1 Constant signal
o242* Alarm for uncritical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o283 Inversion of contact function for output 1 - 2 1
1 Normally open, NO
2 Normally closed, NC
* = Only when o200 is set to 4.