DAAB OUTPUT CARD DB407 INSTRUCTION MANUAL
16
No. Name Range Factory Setting
o422 Function during warning time 1 - 2 1
1 Output signal disabled during warning in other output
2 Output signal as congured in o410-o413
o423 Flashing frequency 0.1-2.0 seconds 0.5
o430* Alarm if there is an error as congured in o431-o439. e
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes 0.00
o431* Alarm for faulty safety edge. Time as in o430. 0 - 1 0
0 Constant signal
1 Active
o432* Alarm for critical error message in display 0 - 1 0
0 Constant signal
1 Active
o433* Alarm if stop circuit interrupted 0 - 1 0
0 Disabled
1 Constant signal
o434* Alarm if door open 0 - 1 0
0 Disabled
1 Constant signal
o435* Alarm if door is in mid position 0 - 1 0
0 Disabled
1 Constant signal
o436* Alarm if door is in closed position 0 - 1 0
0 Disabled
1 Constant signal
o437* Alarm if vehicle loop 1 is activated 0 - 1 0
0 Disabled
1 Constant signal
o438* Alarm if vehicle loop 2 is activated 0 - 1 0
0 Disabled
1 Constant signal
o439* Alarm if photocell interrupted 0 - 1 0
0 Disabled
1 Constant signal
o442* Alarm for uncritical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o483 Inversion of contact function for output 1 - 2 1
1 Normally open, NO
2 Normally closed, NC
* = Only when o400 is set to 4.