7
No. Name Range Factory Setting
o130* Alarm if there is an error as congured in o131-o139. e
alarm is activated for at least the time set in this channel.
0.00-9.59 minutes 0.00
o131* Alarm for faulty safety edge. Time as in o130. 0 - 1 0
0 Disabled
1 Constant signal
o132* Alarm for critical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o133* Alarm if stop circuit interrupted 0 - 1 0
0 Disabled
1 Constant signal
o134* Alarm if door open 0 - 1 0
0 Disabled
1 Constant signal
o135* Alarm if door is in mid position 0 - 1 0
0 Disabled
1 Constant signal
o136* Alarm if door is in closed position 0 - 1 0
0 Disabled
1 Constant signal
o137* Alarm if vehicle loop 1 is activated 0 - 1 0
0 Disabled
1 Constant signal
o138* Alarm if vehicle loop 2 is activated 0 - 1 0
0 Disabled
1 Constant signal
o139* Alarm if photocell interrupted 0 - 1 0
0 Disabled
1 Constant signal
o142* Alarm for uncritical error message in display 0 - 1 0
0 Disabled
1 Constant signal
o183 Inversion of contact function for output 1 - 2 1
1 Normally open, NO
2 Normally closed, NC
* = Only when o100 is set to 4.