ISTRUZIONI PER L'INSTALLAZIONE E LA MANUTENZIONE
INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE
INSTRUCTIONS POUR L'INSTALLATION ET LA MAINTENANCE
INSTALLATIONS- UND WARTUNGSANLEITUNGEN
INSTRUCCIONES DE INSTALACIÓN Y MANTENIMIENTO
РУКОВОДСТВО ПО МОНТАЖУ И ТЕХНИЧЕСКОМУ ОБСЛУЖИВАНИЮ
INSTRUCTIES VOOR INSTALLATIE EN ONDERHOUD
INSTALLATIONS- OCH UNDERHÅLLSANVISNING
KURMA VE BAKIM BİLGİLERİ
ΟΔΗΓΙΕΣ ΓΙΑ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΚΑΙ ΤΗ ΣΥΝΤΗΡΗΣΗ
INSTRUCTIUNI PENTRU INSTALARE SI INTRETINERE
PWM 203
PWM 202
PWM 201
PWM 407
PWM 405
PWM 404
PWM 420
PWM 415
PWM 410

Table of Contents

Questions and Answers

  • E
    Emma GreeneAug 19, 2025
    What to do if DAB PUMPS Inverter display shows OC?
    • S
      Shawn BeasleyAug 19, 2025
      If the DAB PUMPS Inverter display shows OC, it could be due to several reasons: * Incorrect pump current setting (RC): Set RC with the current according to the type of connection (star or delta) as stated on the motor dataplate. * Excessive absorption: Ensure that the motor has all phases connected. * Pump blocked: Check that the impeller or motor is not blocked or obstructed by foreign bodies. * Inverted direction of rotation: Check the direction of rotation.
  • A
    Adriana FritzAug 23, 2025
    What to do if DAB PUMPS Inverter display shows BPx?
    • T
      Toni RiggsAug 23, 2025
      If the DAB PUMPS Inverter display shows BPx, it indicates a problem with the pressure sensor. Here’s what to check: * Pressure sensor disconnected: Check the pressure sensor cable connection. Note that BP1 refers to the sensor connected to Press 1, BP2 to Press 2, and BP3 to the current sensor connected to J5. * Pressure sensor faulty: If the connection is secure, the pressure sensor may be faulty and needs replacement.
  • R
    Rebecca McdonaldAug 26, 2025
    What to do if DAB PUMPS Inverter display shows OF?
    • T
      Tyler BellAug 26, 2025
      If the DAB PUMPS Inverter display shows OF, it could be due to: * Excessive absorption: Check the type of connection (star or delta), ensure the motor doesn't absorb current over the maximum admissible value for the inverter, and verify that all motor phases are connected. * Pump blocked: Check that the impeller or motor is not blocked or obstructed by foreign bodies. Also, check the motor phase connections. * Pump absorbs high current on start-up: Reduce the acceleration parameter AC.
  • N
    Nicholas WilsonAug 28, 2025
    Why does the DAB PUMPS Inverter pump never stop?
    • M
      meganjohnsonAug 28, 2025
      The DAB PUMPS Inverter pump might never stop because: * Minimum flow threshold FT setting too low: Set a higher FT threshold. * Short observation time: Set a higher FZ threshold. * Unstable pressure regulation: Wait for the self-learning process or run quick learning mode. * Incompatible use: Ensure that the system meets the operating requirements without the flow sensor. Attempt to reset by pressing MODE SET + - to recalculate conditions without the flow sensor.
  • J
    Jose BryantAug 30, 2025
    Why does the DAB PUMPS Inverter pump stop even when not required?
    • W
      Wendy CamachoAug 30, 2025
      The DAB PUMPS Inverter pump might stop even when not required due to: * Short observation time: Wait for the self-learning process or run quick learning mode. * Minimum frequency FL setting too high: If possible set a lower FL value. * Excessively high setting of minimum shutdown frequency FZ: Enter a lower threshold for FZ.
  • J
    Jean ChenSep 2, 2025
    What to do if DAB PUMPS multi inverter system does not start?
    • D
      Dwayne RomeroSep 2, 2025
      If the DAB PUMPS multi inverter system does not start, it might be because one or more inverters have an incorrect RC current setting. Check the RC current setting on each inverter.
  • W
    wvalenciaSep 4, 2025
    What does it mean when DAB PUMPS Inverter display shows: Press + to align this config?
    • J
      Jessica DixonSep 4, 2025
      If the DAB PUMPS Inverter display shows 'Press + to align this config', it means that one or more inverters have sensitive parameters that are not aligned. Press the '+' button on the inverter that has the most recent and correct configuration of parameters.
  • P
    Peter BowersSep 6, 2025
    How to troubleshoot regulation pressure greater than SP on DAB PUMPS Inverter?
    • A
      amarshallSep 6, 2025
      If the regulation pressure is greater than SP on your DAB PUMPS Inverter, it is likely that the FL setting is too high. Reduce the minimum operating frequency FL (if the electric pump enables this).
  • M
    Mr. Cameron StarkSep 8, 2025
    Why DAB PUMPS Inverter parameters are not propagatable in a multiple inverter system?
    • W
      Wyatt CastilloSep 8, 2025
      If the parameters are not propagatable in your DAB PUMPS multiple inverter system, it could be due to: * Different passwords: Access each inverter individually and enter the same password on all, or remove the password. * Presence of non-propagatable configurations: Modify the configuration so that it is propagatable; it is not admitted to propagate configurations with FI=0 or FZ=0.
  • M
    Monica CallahanSep 12, 2025
    What to do if DAB PUMPS Inverter display shows EC?
    • G
      Gary HarrisSep 12, 2025
      If the DAB PUMPS Inverter display shows EC, it means that the pump current (RC) is not set. You should set the parameter RC.

Summary

KEY

WARNINGS

LIABILITY

1. GENERAL INFORMATION

1.1 Applications

List of typical applications for the inverter system.

1.2 Technical specifications

Detailed technical data and specifications of the inverter models.

2. INSTALLATION

2.1 Fixing the unit

Instructions on how to securely mount the inverter unit.

2.2 Connections

2.2.1 Electrical connections

Specific guidance on wiring the electrical components of the inverter.

2.2.2 Hydraulic connections

2.2.3 Connection of sensors

How to connect pressure and flow sensors to the inverter.

2.2.4 Utility input and output electrical connections

2.2.4.1 OUT 1 and OUT 2 output contacts

Configuration and specifications for the inverter's output contacts.

3. KEYBOARD AND DISPLAY

3.1 Menus

Overview of the inverter's menu structure and access methods.

3.2 Access to menus

3.2.1 Direct access with button combinations

Method for accessing menus using specific button sequences.

3.2.2 Access by name via drop-down menus

3.3 Structure of menu pages

Describes how menu pages are presented on the display.

3.4 Parameter setting block via Password

4. MULTI INVERTER SYSTEM

4.1 Introduction to multi inverter systems

Overview of the concept and benefits of multi-inverter systems.

4.2 Setting up a multi inverter system

4.2.1 Communication cable (Link)

How to connect inverters for communication using the link cable.

4.2.2 Sensors

4.2.2.1 Flow sensors

Connecting and configuring flow sensors for multi-inverter operation.

4.2.3 Connection and setting of the optical coupling inputs

4.3 Multi inverter operating parameters

4.3.1 Parameters related to multi inverter systems

Parameters specific to multi-inverter configurations.

4.4 Initial start-up of multiple inverter system

4.5 Multi-inverter settings

4.5.1 Assigning the start-up order

How the sequence of inverter start-up is determined.

5. POWER-UP AND START-UP

5.1 Initial power-up operations

Steps for the first time power-up and parameter configuration.

5.2 Troubleshooting on initial installation

6. KEY TO INDIVIDUAL PARAMETERS

6.1 User menu

Access to user-configurable parameters for daily operation.

6.2 Monitor menu

Access to diagnostic and monitoring parameters.

6.3 Setpoint menu

6.3.1 SP: Setting the setpoint pressure

Sets the main system operating pressure value.

6.3.2 Auxiliary pressure settings

Configures up to four auxiliary pressure setpoints.

6.4 Manual menu

6.4.1 FP: Test frequency setting

Sets a test frequency for manual pump operation.

6.5 Installer menu

6.5.1 RC: Electric pump rated current setting

Sets the rated current of the electric pump.

6.5.2 RT: Setting the direction of rotation

Inverts the motor rotation direction if it is incorrect.

6.5.3 FN: Rated frequency settings

Sets the rated frequency of the electric pump.

6.5.4 OD: Type of system

6.5.5 RP: Setting the pressure drop for restart

6.5.8 MS: Measurement system

6.5.9 FI: Flow sensor setting

6.5.9.1 Operation without flow sensor

Settings for systems operating without a flow sensor.

6.5.12 FZ: Setting zero flow frequency

6.5.13 FT: Shutdown threshold setting

6.5.14 SO: Dry running factor

6.6 Technical Assistance Menu

6.6.1 TB: Water failure block time

Sets the delay time for water failure notification.

6.6.6 FS: Maximum rotation frequency

6.6.7 FL: Minimum rotation frequency

6.6.8 Setting the number of inverters and reserves

6.6.8.1 NA: Active inverters

Sets the maximum number of inverters involved in pumping.

6.6.8.3 IC: Reserve configuration

6.6.9 ET: Exchange time

6.6.10 CF: Carrier frequency

6.6.11 AC: Acceleration

6.6.12 AE: Enabling the anti-blocking function

6.6.13 Setup of auxiliary digital inputs IN1, IN2, IN3, IN4

6.6.13.2 Setting the external float function

Configures the float switch for water failure detection.

6.6.13.3 Setting the auxiliary pressure input function

6.6.13.4 Setting the system enable and fault reset

6.6.13.5 Setting low pressure detection (KIWA)

6.6.14 Setup of outputs OUT1, OUT2

6.6.14.1 01: Output 1 function setting

Sets the function for output 1, typically for alarms.

6.6.14.2 02: Output 2 function setting

Sets the function for output 2, typically for pump running status.

7. PROTECTION SYSTEMS

7.1 Description of blocks

Explains various block conditions and error messages.

7.2 Manual reset of error conditions

7.3 Auto-reset of error conditions

8. RESET AND DEFAULT SETTINGS

8.1 General system reset

How to perform a general system reset.

8.2 Default settings

Information on the factory default parameter settings.

8.3 Restoring default settings

Steps to restore the inverter to its factory default settings.

DAB PUMPS PWM 203 Specifications

General IconGeneral
BrandDAB PUMPS
ModelPWM 203
CategoryInverter
LanguageEnglish