Zero key Operation Range selection
F08
0 Activated within 2% of Max. Capacity
1 Activated within 5% of Max. Capacity
2 Activated within 10% of Max. Capacity
3 Activated within 20% of Max. Capacity
4 Activated within 100% of Max. Capacity
Tare key Operation Range selection
F09
0 Activated within 10% of Max. Capacity
1 Activated within 20% of Max. Capacity
2 Activated within 50% of Max. Capacity
3 Activated within 100% of Max. Capacity
External Input Selection
F11
Set Value Input 1 Input 2 Input 3 Input 4
0 Zero Tare Tare Reset Print
1 Zero Tare/Reset Sub-total Print
Communication setting
Serial I/F Communication Speed selection
F31
0 600bps
1 1,200bps
2 2,400bps
3 4,800bps
4 9,600bps
5 19,200bps
6 38,400bps
7 57,600bps
8 115,200bps
Serial I/F Communication Mode setting (Under F33-00 setting, only)
F32
0 Stream Mode : Continuous Data transfer
1 Finish Mode : Single time data transfer, when the weight is finish
2 Print Mode : Single time data transfer, when print key input
21 / 41