11
Installation Requirements
Decorative Overlay Panels
Model
Series
A B C
IF42 17¹⁄
8(43.5 cm) 23¹⁄8(58.74 cm) 40½” (102.9 cm)
IF48 19
5
8(49.9 cm) 26
5
8(67.6 cm) 46½” (118.1 cm)
Backer Panels
Model
Series
D E F
IF42 16
7
8
(42.9 cm) 22
7
8
(58.1 cm) 40½” (102.9 cm)
IF48 19
3
8
(49.2 cm) 26
3
8
(67.0 cm) 46½” (118.1 cm)
70¹⁄2"
(179.1 cm)
70¹⁄2
"
(179.1 cm)
E
D
B
Refrigerator Panel for
Freezer Panel for
Non-Dispenser Models all Models
Handle-Side
Backer
Offset
¹⁄8" (3.2 mm)
A
¹⁄8
"
(3.2 mm)
Backer Bottom Offset
¹⁄8
"
(3.2 mm)
24 "
(61.1 cm)
35”
(88.9 cm)
Framed MethodFrameless Method
34³⁄8"
(87.3 cm)
34³⁄8
"
(87.3 cm)
23
3
8
"
(59.4 cm)
D
D
D
A
A
D
Bottom Offset
¹⁄8
"
(3.2 mm)
7
16
Freezer Panels for
Dispenser Models
A
11
15
16
"
(30.5 cm)
35”
(88.9 cm)
11
"
(29.5 cm)
5
8
Dispenser
cutout is
centered
left to right
Handle-Side
Offset
¹⁄8" (3.2 mm)
Handle-Side
Offset
¹⁄8
¹⁄8
" (3.2 mm)
Handle-Side
Offset
¹⁄8" (3.2 mm)
Backer
Backer
Bottom Offset
Backer
Backer
Backer
Backer
Top Freezer Panel
Bottom Freezer Panel
Top Offset
"
(1.1 cm)
23
3
8
"
(59.4 cm)
¹⁄16 "
(180.5 cm)
71
Custom Handles
Dacor recommends handles with larger D-style pulls. If using
screws with thick heads, they must be countersunk into the panel
before installing the handles.
Any handle designed for use with an appliance should produce
satisfactory results. Mounting screw length varies with the total
thickness of the panels.
IMPORTANT: Dacor does not advise the use of single pull knobs.
20” Typ.
(50.6 cm)
36” Max.
(91.4 cm)
C
A. Countersunk screw
B. Handle
C. Door panel assembly
Trim frame
surrounding door
A
B
Door
Handle Detail