EasyManuals Logo

Dacor ERV30 Combination Installations

Dacor ERV30
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
COMBINATION INSTALLATIONS
RGC/SGM Series Drop-In Gas Cooktop
with ERV/PRV Series Raised Vent
Document # PGCI-008
Revised 10/04/12 Page 1/2
Stiffener
Cabinet face
Countertop
Floor
3/8” min. (1.0 cm) space
behind raised vent
chassis to clear stiffener
3/8” min. (1.0 cm)
flat countertop overhang
required behind cutout
ERV or PRV series raised
vent: Check raised vent
dimensions/specifications
to determine proper fit
SGM series cooktop
WARNING
• Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
• All appliances must be installed in accordance with the
accompanying installation instructions.
All tolerances +1/16” (+1.6 mm), -0, unless otherwise noted.
Cutout Dimensions
SIDE VIEW - RGC/SGM SERIES COOKTOP WITH
ERV/PRV SERIES RAISED VENT
IMPORTANT: Be careful to use the correct cutout diagram (on page 2/2) to determine the countertop dimensions. Carefully double check all dimensions
against the table below and the correct diagram before cutting the countertop.
* Total cutout depth, accommodates both the cooktop and raised vent
** IMPORTANT: Notch depth is included in total cutout depth (D). DO NOT add notch depth to total cutout depth (D).
RGC or SGM series cooktop
Countertop Dimensions
Installation Type
Cutout
Diagram
C (minimum) D E F G H
RGC/SGM304 with
ERV30[15] or PRV30
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
27 3/4”
(68.6 cm)
NA NA NA
RGC/SGM365 with
ERV36[15] or PRV36
Figure 1
(Square)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
33 5/8”
(85.4 cm)
NA NA NA
RGC/SGM466 with
PRV46
Figure 2
(Notched)
3/8”
(1.0 cm)
22 1/2” *
(57.2 cm)
44 3/4”
(113.7 cm)
43 1/2”
(110.5 cm)
5/8”
(1.6 cm)
2 5/8” **
(6.7 cm)

Other manuals for Dacor ERV30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dacor ERV30 and is the answer not in the manual?

Dacor ERV30 Specifications

General IconGeneral
CategoryVentilation Hood
ModelERV30
TypeWall Mount
Width30 inches
Ventilation TypeDucted
CFM600 CFM
Number of Speeds4
LightingLED
MaterialStainless Steel
Filter TypeBaffle