219
AUTO GREASING (OPTION)
Auto control
Grease pump operates periodically
set by control unit, singnal lamp “ON”
simultaneously with grease pump
operation and keep lighting 42 second
and “OFF”. If the pressure in main
line is less than specified value,
singnal lamp keeps lighting “ON” even
at the rest time. When Battery main
switch is turned “OFF”, the signal
lamp also “OFF”. After troubleshooting,
if normal pressure is available, the
signal lamp operation returns to
normal condition.
Operation
In main switch “ON”, the operation
and rest time repeat periodically.
When main switch “OFF”, time
recording stops and is memoried to
the unit. Main switch “ON” again, time
recording continues and the system
operates again.
Manual operation
Grease can be pumped manually by
pushing manual switch(DK) equipped
beside of unit. After manual operation,
the rest time set returns to “O”.
Grease replenishment
Check the amount grease in the
transparent jar of gear pump unit,
frequently and replenish if necessary,
use clean and same type grease.
Pump operation time 154 second
Signal lamp lighting time 42 second
Rest time (adjustable)
0.5,
1.2Ŕ11hours