37
DESCRIPTION
Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect
Power ON and Voltage less than 4.25V, and then send Reset Signal.
Reset(8)
MICOM
18
CC9
103
R12
1K
+
CE4
4.7µF
50V
IC5
7042P
R13
5.6K
5V
4.25V
H
L
t
t
POWER
ON
Vcc (+5V)
DELAY TIME
FOR POWER ON
RESET