8-2. Refrigerant Flow Sound
8-3. Fan Noise
- The fan is sending out cold air to circulate each corner of the compartsment.
- When the air is touching the surface of louver or liner wall, such sound can make.
TROUBLE SHOOTING
Remarks
Remarks
Water flowing or hiss
sounds?
Start
Hiss or sizzling sound
when comprssor starts
/
sto
p
s?
Any shaking sound from
Freezer compartment when
compressor works?
Attach an absorber gum
on the capillary tube
No
No
Yes
Apply a gum on the
accumulator
Yes
No
Fasten the evaporator tightly
not to touch liner surfaces.
Yes
Explain refrigerator work
mechanism and sound to the
user or customer
- Water flowing sound, hiss or sizzling sound can make while
refrigerant in the pipes is changing from liquid to gas state when
compressor starts or stops.
- It is normal sound.
Fan is touching the
something?
Start
Fan Motor assembly is
moving or shaking?
Motor has its own noise or
vibration when working?
Damaged / transformed?
Set it right not to touch
No
No
Yes
Set it right not to move
Yes
Chenage the new
Yes
46