9. Door opening alarm continues after closing
TROUBLE SHOOTING
Door switch pushing well?
Start
Attach a thin pad on the
door liner or change the
door assmbly.
No
Door switch is soaked
with water or there is
water in the switch?
Change the door switch
Yes
Yes
PCB input is OK?
Repair any disconnection of wires
and defective door switch
No
Yes
Connector insertion to
Main PCB is OK?
Repair the defective connection
No
Yes
No
Check if interior light is ON
Door switch itself is ok?
Change the new
Yes