8
EN
GDA 3500 / 3500E / 3500DFE / 6500 / 6500E / 7500E / 7500E-3
GDA 7500DPE-3 / 7500DFE / 8500E / 8500E-3 / 9500DPE-3
• Do not allow multiple devices to be connected at the same time.
• Run the generator for 3 minutes without connecting the load.
• Various devices need more power when starting.
• Connect the devices one after the other according to the maximum power allowed by your
generator.
• Before connecting, make sure that all devices are in good working order.
• If the connected device no longer works or stops suddenly, disconnect the load immediately
using the emergency switch, turn o the device and test it.
• Remember to turn o all devices before stopping the generator.
• If the display (voltmeter) shows a voltage value of 230V ±10% (50Hz), you can use the generator.
• If the voltage value on the display (voltmeter) goes beyond 230V ±10% (50Hz), it is necessary to
stop the generator
• DC 12V cannot be used simultaneously with 230V.
• The generator must be connected to the mains by a qualified person.
• Incorrect connection may cause serious damage.
Fill in the fuel
tank with
gasoline
Turn the ignition
key to start
the engine (for
electric start
models)
Check oil level
Put the choke
to the „OPEN’’
(RUN)
Open the fuel
cock
Connect
the power
consumer(s) to
the generator
Put the ignition
switch to „ON’’
Put the choke
to the „CLOSE’’
(CHOKE) position
Gently pull the
starter handle to
start the engine
ENGINE STOP
• Turn o the power to devices connected to the generator.
• Pull starting: Put the ignition switch to OFF.
• Electric starting: Turn the key OFF.
• Close the fuel cock.
GENERATOR EMERGENCY SWITCH
DAEWOO generators are equipped with an emergency switch
(fig. 2). When the generator is running
with the load connected, the emergency switch must be in the ON position.
In the event of an overload protection trip, the emergency switch will automatically move to the OFF
position and stop the generator. This means that the power plant is overloaded or the consumer is faulty.
Switch o the generator immediately, check the serviceability of the consumers and the generator.
Stopping the generator with connected power consumers can damage the generator.
IMPORTANT!