Alarm Control Panel Installer Manual
8
Supports abnormality alarm, including network disconnected alarm, PSTN fault alarm, tampering
alarm, low battery alarm, battery loss alarm, power loss alarm, and keyboard faults alarm.
In-field firmware upgradable.
App-based system control through DMSS.
Terms and Definitions 1.3
Refer to the terms and definitions that are used in the Manual as below.
Table 1-1 Terms and definitions
Term
Definition
Area
The 8 Areas that can be armed.
Zone
Protection zones under Area.
Partition
The scope of Partition is larger than Zone and under Area.
Numeric key
Key 09 on the Keypad.
Function key
The other keys except Numeric keys, such as ESC and ENTER.
Key combination
+ Numeric key.
User Menu
Menus programmed by the User.
Installer Menu
Menus programmed by the TECHNICIAN.
Access Code
A specified code, from 4 to 6 digits, that allows the user to operate the
Keypad.
TECHNICIAN
A person that is authorized to access the Installer Menu to program
the system.
1EOL
The detector type can be NO or NC, and returns two status: Normal
and Alarm (short circuit and broken circuit are considered to be Alarm
status).
2EOL
The detector type can be NO or NC, and returns four status: Normal,
Alarm, Tamper, and Short Circuit prevention.
3EOL
The detector type can be NO or NC, and returns five status: Normal,
Alarm, Tamper, Anti-masking, and Short Circuit prevention.