Daijitsu AM-H12A4/S Portable Air Conditioner
Fan Speed – Cooling and Heating Mode
Cooling Mode - when in this mode air is exhausted from the vent side of the unit as shown if
figure 1. The fan speed is variable and noticeable when changed from Low – Med – High
.
Figure 1
Heat Mode – when in this mode air is exhausted from the rear end of the unit as shown in
Figure 2. The fan speed is not variable – does not change but fixed at one speed. [This is
not a fault] - User guide page 8 steps 3 is a misprint – Fan speed cannot be changed.
Figure 2
Note: - Exhaust air duct must be connected to extract hot or cold air from the room. In cool
mode duct must be connected to figure 2 and in heat mode connected to figure 1. Refer to
user guide for instructions.
Air Flow Volume - Cooling Mode
Low: 410m^3/h
Med: 420m^3/h
High: 450m^3/h
Question and Answer IconNeed help?

Do you have a question about the Daijitsu AM-H12A4/S and is the answer not in the manual?

Daijitsu AM-H12A4/S Specifications

General IconGeneral
BrandDaijitsu
ModelAM-H12A4/S
CategoryAir Conditioner
LanguageEnglish

Summary

Fan Speed and Modes

Cooling Mode Airflow

Describes cooling mode air exhaust, variable fan speed, and specific airflow volumes.

Heating Mode Operation

Details heating mode, fixed fan speed, and operational steps for heating.

Air Conditioner Parts Identification

Front View Components

Identifies control panel, outlets, inlets, and other parts visible from the front.

Rear View Components

Identifies rear panel and air outlet components.

Duct Mount Instruction

Duct Connection Steps

Details how to connect the exhaust duct to the unit and adapter.

Window Kit Installation

Window Opening Adjustments

Explains installation for vertical and horizontal windows, including minimum/maximum openings.