3 | Specific installer safety instructions
Installer reference guide
19
2MXM-A, 3MXM-A, 4MXM-A, 5MXM-A
R32 Split series
4P600463-5E – 2021.12
WARNING
Before carrying out any maintenance or repair activity, ALWAYS switch off the
circuit breaker on the supply panel, remove the fuses or open the protection
devices of the unit.
Do NOT touch live parts for 10 minutes after the power supply is turned off
because of high voltage risk.
Please note that some sections of the electric component box are hot.
Make sure you do NOT touch a conductive section.
Do NOT rinse the unit. This may cause electric shocks or fire.
DANGER: RISK OF ELECTROCUTION
Use this compressor on a grounded system only.
Turn the power off before servicing the compressor.
Reattach the switch box cover and service lid after servicing.
CAUTION
ALWAYS wear safety glasses and protective gloves.
DANGER: RISK OF EXPLOSION
Use a pipe cutter to remove the compressor.
Do NOT use the brazing torch.
Use approved refrigerants and lubricants only.
DANGER: RISK OF BURNING/SCALDING
Do NOT touch the compressor with bare hands.
Troubleshooting (see
"15Troubleshooting"[
4
69]
)
WARNING
When carrying out an inspection on the switch box of the unit, ALWAYS make
sure that the unit is disconnected from the mains. Turn off the respective circuit
breaker.
When a safety device was activated, stop the unit and find out why the safety
device was activated before resetting it. NEVER shunt safety devices or change
their values to a value other than the factory default setting. If you are unable to
find the cause of the problem, call your dealer.
WARNING
Prevent hazards due to inadvertent resetting of the thermal cut-out: power to this
appliance MUST NOT be supplied through an external switching device, such as a
timer, or connected to a circuit that is regularly turned ON and OFF by the utility.
DANGER: RISK OF ELECTROCUTION
When the unit is NOT operating, the LEDs on the PCB are turned OFF in order to
save power.
Even when the LEDs are OFF, the terminal block and the PCB may be powered.

Table of Contents

Other manuals for Daikin 4MXM80A2V1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 4MXM80A2V1B and is the answer not in the manual?

Daikin 4MXM80A2V1B Specifications

General IconGeneral
BrandDaikin
Model4MXM80A2V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals