Daikin Altherma FWXV15AATV3 Specifications

General IconGeneral
ModelFWXV15AATV3
CategoryHeat Pump
Power SourceElectric
TypeAir to Water
RefrigerantR32
Energy Efficiency Class (Heating)A++
Sound pressure level (Outdoor)50 dBA
Noise Level (Indoor Unit)35 dB
Noise Level (Outdoor Unit)50 dB
Dimensions (Indoor Unit)900 x 320 x 700 mm
Dimensions (Outdoor Unit)900 x 320 x 700 mm

Summary

Conformity

Symbols

GENERAL

General warnings

Important safety and operational guidelines to follow after unpacking and before initial use of the Daikin unit.

Fundamental safety rules

Essential safety precautions concerning electrical and water usage, child supervision, and appliance modification.

Product range

Overview of the available Daikin heat pump convector types (FWXV and FWXM) and their size variations.

Nominal technical features

Key technical specifications for the FWXV/FWXM series, including water content, pressure, temperatures, and power.

Overall dimensions Heat pump convector

Detailed physical dimensions for both FWXV and FWXM series heat pump convectors, presented with diagrams.

INSTALLATION

Positioning the unit

Guidelines for optimal placement of the unit, avoiding direct sunlight, heat, dampness, and obstructions.

Installation modes

Details on different mounting phases and considerations for correct installation procedures.

Minimum installation distances

Specifies required clearances around the unit for proper ventilation and operation.

Access to the body machine

Step-by-step instructions for removing and refitting the upper grill and front panel for internal access.

Remove side

Instructions on how to remove the side panel of the machine body for access.

Vertical floor or wall installation (FWXV-series)

Guidance for mounting the FWXV-series units on floors or walls, including bracket installation.

Horizontal or ceiling installation (FWXM-series)

Instructions for installing FWXM-series units horizontally or on ceilings, including condensation drainage.

Hydraulic connections

Details on connecting hydraulic lines, including pipe diameter, insulation, and sealing methods.

Condensation discharge

Procedures for setting up the condensation discharge network, including inclination and pump requirements.

Filling the system

Steps for filling the hydraulic system, ensuring all valves are open and power is off.

Evacuating air while filling the system

Process for removing air from the hydraulic system during the filling procedure.

Electrical connections

Guidelines for making electrical connections, emphasizing safety precautions and proper switch requirements.

Maintenance

Importance of routine maintenance for optimal, safe, and reliable operation of the heat pump convector.

Cleaning the outside

Instructions for cleaning the exterior surfaces of the unit safely and effectively.

Cleaning air suction filter

Procedure for removing and cleaning the air suction filters to maintain unit efficiency and air quality.

Energy saving tips

Recommendations for optimizing energy efficiency, such as filter maintenance and managing room conditions.

TROUBLESHOOTING

Troubleshooting

General advice for handling water leaks or anomalous functioning, and when to contact service.

Table of anomalies and remedies

A comprehensive table listing common effects, their causes, and recommended remedies for troubleshooting.

Related product manuals