SiBE04 - 809
[Applied Models]
In
verter Pair :
Heat Pump
In
ver
ter P
air
W
all Mounted
T
ype E-Series
2
Table of Contents
Default Chapter
3
Table of Contents
3
Introduction
6
Safety Cautions
6
Used Icons
10
Part 1 List of Functions
12
List of Functions
13
Part 2 Specifications
14
Specifications
15
Part 3 Printed Circuit Board Connector Wiring Diagram
18
Printed Circuit Board Connector Wiring Diagram
19
Indoor Unit
19
Outdoor Unit
21
Part 4 Function and Control
24
Main Functions
25
Frequency Principle
25
Power-Airflow Flap, Wide-Angle Louvres and Auto-Swing
27
Operation Starting Control
28
Fan Speed Control for Indoor Units
29
Programme Dry Function
30
Automatic Operation
31
Thermostat Control
32
NIGHT SET Mode
33
Intelligent Eye
34
Inverter POWERFUL Operation
35
Other Functions
36
Function of Thermistor
38
Heat Pump Model
38
Control Specification
39
Mode Hierarchy
39
Frequency Control
40
Controls at Mode Changing / Start-Up
42
Discharge Pipe Temperature Control
45
Input Current Control
46
Freeze-Up Protection Control
47
Heating Peak-Cut Control
48
Fan Control
49
Liquid Compression Protection Function 2
49
Defrost Control
49
Electronic Expansion Valve Control
51
3.12 Malfunctions
54
Forced Operation Mode
55
3.14 Additional Function
55
Part 5 Operation Manual
56
System Configuration
57
Instruction
58
Safety Precautions
58
Installation Site
59
Electrical Work
59
Names of Parts
60
Remote Controller
62
Preparation before Operation
63
AUTO · DRY · COOL · HEAT · FAN Operation
66
Adjusting the Airflow Detection
68
POWERFUL Operation
70
OUTDOOR UNIT QUIET Operation
71
INTELLIGENT EYE Operation
72
TIMER Operation
74
Care and Cleaning
76
Air Filter
77
Before a Long Idle Period
78
Troubleshooting
79
Disposal Requirements
81
Part 6 Service Diagnosis
82
Caution for Diagnosis
83
Problem Symptoms and Measures
84
Service Check Function
85
Troubleshooting
88
Error Codes and Description
88
Indoor Unit PCB Abnormality
89
Freeze-Up Protection Control or High Pressure Control
90
Fan Motor (DC Motor) or Related Abnormality
92
Thermistor or Related Abnormality (Indoor Unit)
94
Front Panel Open / Close Fault
95
Signal Transmission Error (between Indoor and Outdoor Unit)
96
Signal Transmission Error (between Indoor Unit and Wired Remote Controller)
97
Unspecified Voltage (between Indoor and Outdoor Units)
98
Outdoor Unit PCB Abnormality
99
OL Activation (Compressor Overload)
100
Compressor Lock
101
DC Fan Lock
102
Input over Current Detection
103
Four Way Valve Abnormality
104
Discharge Pipe Temperature Control
106
High Pressure Control in Cooling
108
Compressor System Sensor Abnormality
110
Position Sensor Abnormality
111
DC Voltage / Current Sensor Abnormality
113
Thermistor or Related Abnormality (Outdoor Unit)
114
Electrical Box Temperature Rise
116
Radiation Fin Temperature Rise
118
Output over Current Detection
120
Insufficient Gas
122
Low-Voltage Detection or Over-Voltage Detection
124
Signal Transmission Error on Outdoor Unit PCB
126
Check
127
How to Check
127
Sibe04
128
Thermistor Resistance Check
129
Installation Condition Check
130
Discharge Pressure Check
131
Outdoor Unit Fan System Check
131
Power Supply Waveforms Check
132
Power Transistor Check
133
Part 7 Removal Procedure
134
Indoor Unit
135
Removal of Air Filter
135
Removal of Front Grille
137
Removal of Assembly of Front Panel Mechanism
143
Removal of Lamp Cover
146
Removal of Horizontal Blade
147
Removal of Reduction Motor
149
Removal of Outlet Grille
152
Removal of Vertical Blades and Swing Motor
153
Removal of Electrical Box
157
Removal of PCB
163
Removal of Heat Exchanger
169
1.12 Removal of Fan Rotor and Fan Motor
172
Outdoor Unit
175
Removal of Panels and Fan Motor
175
Removal of Electrical Box
184
Removal of Reactor and Partition Plate
188
Removal of Sound Blanket
190
Removal of Four Way Valve
192
Removal of Compressor
195
Removal of PCB
197
Part 8 Others
200
Others
201
Test Run from the Remote Controller
201
Jumper Settings
202
Application of Silicon Grease to a Power Transistor and a Diode Bridge
203
Part 9 Appendix
204
Piping Diagrams
205
Indoor Units
205
Outdoor Units
205
Wiring Diagrams
206
Indoor Units
206
Outdoor Units
206
Index
208
Other manuals for Daikin ATXG35EV1B
Installation Manual
15 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Daikin ATXG35EV1B and is the answer not in the manual?
Ask a question
Daikin ATXG35EV1B Specifications
General
Category
Air Conditioner
Cooling Capacity
3.5 kW
Heating Capacity
4.0 kW
Power Supply
220-240 V, 50 Hz
Energy Efficiency Ratio (Cooling)
3.5
Related product manuals
Daikin ATXG25EV1B
214 pages
Daikin ATXF35D
36 pages
Daikin ATXB25C
32 pages
Daikin ATXD50CV4
30 pages
Daikin ATX35BVMB
201 pages
Daikin ATX20J2V1B
26 pages
Daikin ATX25J2V1B
26 pages
Daikin ATXS25DVMB
248 pages
Daikin ATX25K2V1B
30 pages
Daikin ATXS35DVMB
248 pages
Daikin ATXS25CVMB
298 pages
Daikin ATXS20DVMB
248 pages