3 | Components
Service manual
127
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
a b
a Backup heater thermal protector sensor
b Backup heater
4 Loosen and remove the 2 screws that fix the backup heater thermal protector
bracket to the switch box.
b c a
ac d
a Screw
b Backup heater thermal protector bracket
c Screw
d Backup heater thermal protector
5 Loosen and remove the 2 screws that fix the backup heater thermal protector
to the bracket.
6 Disconnect the wires from the backup heater thermal protector terminals.
7 Remove the backup heater thermal protector and sensor from the unit.
8 To install the backup heater thermal protector, see "Repair
procedures"[4126].
To install the backup heater thermal protector
1 Route the backup heater thermal protector sensor and wiring through the
grommet of the switch box.
2 Insert the backup heater thermal protector sensor in the backup heater.