Installation, Maintenance and Operation Manual
DEIMHP0140521_00EN
Air to water heat pump units with scroll compressors
EWYT~CZ / EWAT~CZ

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin EWYT090CZP-A2 and is the answer not in the manual?

Daikin EWYT090CZP-A2 Specifications

General IconGeneral
ModelEWYT090CZP-A2
CategoryHeat Pump
Energy Efficiency ClassA++
RefrigerantR32
Power Supply400/3/50 V/Ph/Hz

Summary

1. Introduction and Safety

1.1. Residual Risks and Safety Precautions

General safety precautions and risks associated with the unit's operation and maintenance.

1.3. Refrigerant Information (R32)

Details about the R32 refrigerant, its properties, classification, and safety considerations.

1.4. Installation Location Guidelines

Guidelines for unit installation location, ventilation, and compliance with codes and standards.

1.4. Installation Location Guidelines (R32 Safety)

Additional guidelines for R32 safety in machinery rooms and open-air installations.

2. Unit Receipt and Inspection

4. Mechanical Installation

4.1. Installation Safety Procedures

Safety precautions for personnel involved in installation and commissioning activities.

4.4. Minimum Space Requirements

Recommended clearances around the unit for proper airflow and maintenance access.

4.4. Minimum Space Requirements (Side-by-Side)

Diagrams illustrating minimum space requirements for units installed side-by-side.

4.7. Water Circuit Connection

General requirements for connecting the unit to the water system, including piping design.

4.7.2. Flow Switch Functionality

Explanation of the flow switch function and its role in protecting the BPHE from freezing.

4.7.2. Flow Switch Setpoints

Table of flow switch setpoints for different unit models.

4.11. Operation Limits Charts

Charts defining operating ranges for cooling and heating modes based on ambient and water temperatures.

4.11. Operation Limits Interpretation

Explains the operational range charts and references selection software.

4.12. System Water Content for Stability

Importance of minimum water content for unit stability and compressor protection.

4.12. System Water Content Tables

Tables providing minimum water content requirements for different unit models.

4.13. Expansion Vessel Calibration

Guidance on calculating and adjusting expansion vessel initial pressure and maximum water volume.

5. Electrical Installation

5.2.3. Safety Device Requirements

Specifies requirements for residual current devices, fuses, and wiring.

6. Operator Responsibilities

7. Maintenance Overview

7.2.4. Refrigerant Circuit Diagrams

9. First Startup Checks

9.1. Pre-Startup Inspection Checklist

Checklist of essential checks to be performed before the initial startup of the unit.

10. Refrigerant Usage Information

10.1. Refrigerant Properties and Environmental Impact

Information on the R32 refrigerant, its GWP, and environmental considerations.