EDSUSE28-956S Capacity tables
RZQ-P, M series 49
1
9.3 FAQ
FAQ18PVJU + RZQ18PVJU
FAQ24PVJU + RZQ24PVJU
Cooling Capacity
230V –60Hz
Indoor Air
Temp.
O u tdoor Air Temp. °FDB
EDB(°FDB) EWB(°FWB)
6 8 77 8 69095104
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
Heating Capacity
230V –60Hz
Indoor Air
Temp.
O u tdoor Air Temp. °FW B
EDB(°FDB)
14 23 32 43 50
TC
MBh
PI
k W
TC
MBh
PI
k W
TC
MBh
PI
k W
TC
MBh
PI
k W
TC
MBh
PI
k W
Cooling
Indoor : 8 0°FDB, 67°FW B
O u tdoor : 95°FDB
Heating
Indoor : 70°FDB
O u tdoor : 47°FDB, 43°FW B
E qui v alent Piping Length
25ft (Lev el Difference : 0)
Hz, V olts
60Hz, 230V
1. The ab o v e data are b ased on the follow ing conditions.
2. Capacities are net, inclu ding a dedu ction for cooling (an addition for heating) for indoor fan motor heat.
3. show s nominal MAX capacities
6 8 .0
72.0
77.0
8 0.0
8 6.0
90.0
57.0
61.0
64.0
67.0
72.0
75.0
11.68
14.21
16.10
1 8 .00
20.79
21.14
8 .9
11.7
12.7
13.7
14.1
12.8
0.60
0.74
0.8 4
0.98
1.19
1.20
11.68
14.21
16.10
1 8 .00
20.06
20.41
8 .9
11.7
12.7
13.7
14.1
12.8
0.66
0.8 4
0.99
1.15
1.33
1.34
11.68
14.21
16.10
1 8 .00
19.32
19.68
8 .9
11.7
12.7
13.7
14.1
12.8
0.76
0.97
1.15
1.35
1.46
1.47
11.68
14.21
16.10
1 8 .00
19.00
19.35
8 .9
11.7
12.7
13.7
14.1
12.8
0.8 1
1.04
1.24
1.45
1.52
1.53
11.68
14.21
16.10
1 8 .00
1 8 .59
1 8 .95
8 .9
11.7
12.7
13.7
14.1
12.8
0.88
1.13
1.35
1.58
1.60
1.61
11.68
14.21
16.10
17.27
17.8 6
1 8 .21
8 .9
11.7
12.7
13.7
14.1
12.8
1.01
1.31
1.57
1.72
1.74
1.75
61
64
6 8
70
72
75
3.59
3.36
3.08
2.94
2.8 0
2.60
23.33
22.22
20.74
20.00
19.26
1 8 .15
23.33
22.22
20.74
20.00
19.26
1 8 .15
3.15
2.96
2.71
2.59
2.47
2.30
23.33
22.22
20.74
20.00
19.26
1 8 .15
2.65
2.49
2.29
2.19
2.10
1.95
23.33
22.22
20.74
20.00
19.26
1 8 .15
2.31
2.18
2.01
1.93
1.8 4
1.72
23.33
22.22
20.74
20.00
19.26
1 8 .15
2.14
2.02
1.8 7
1.79
1.71
1.60
(MBh)
Cooling Capacity
230V –60Hz
Indoor Air
Temp.
O u tdoor Air Temp. °FDB
EDB(°FDB) EWB(°FWB)
6 8 77 8 69095104
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
TC
kBTUH
SHC
MBh
PI
k W
Heating Capacity
230V –60Hz
Indoor Air
Temp.
O u tdoor Air Temp. °FW B
EDB(°FDB)
14 23 32 43 50
TC
MBh
PI
k W
TC
MBh
PI
k W
TC
MBh
PI
k W
TC
MBh
PI
k W
TC
MBh
PI
k W
Cooling
Indoor : 8 0°FDB, 67°FW B
O u tdoor : 95°FDB
Heating
Indoor : 70°FDB
O u tdoor : 47°FDB, 43°FW B
E qui v alent Piping Length
25ft (Lev el Difference : 0)
Hz, V olts
60Hz, 230V
1. The ab o v e data are b ased on the follow ing conditions.
2. Capacities are net, inclu ding a dedu ction for cooling (an addition for heating) for indoor fan motor heat.
3. show s nominal MAX capacities
6 8 .0
72.0
77.0
8 0.0
8 6.0
90.0
57.0
61.0
64.0
67.0
72.0
75.0
15.57
1 8 .94
21.47
24.00
27.72
2 8 .19
14.3
15.3
16.5
1 8 .0
1 8 . 8
17.5
0.96
1.18
1.35
1.57
1.93
1.94
15.57
1 8 .94
21.47
24.00
26.74
27.21
14.3
15.3
16.5
1 8 .0
1 8 .4
17.0
1.05
1.34
1.59
1.8 6
2.15
2.16
15.57
1 8 .94
21.47
24.00
25.76
26.24
14.3
15.3
16.5
1 8 .0
1 8 .0
16.6
1.21
1.57
1.8 6
2.19
2.37
2.38
15.57
1 8 .94
21.47
24.00
25.33
25.8 0
14.3
15.3
16.5
1 8 .0
17.8
16.4
1.30
1.68
2.00
2.35
2.47
2.48
15.57
1 8 .94
21.47
24.00
24.79
25.26
14.3
15.3
16.5
1 8 .0
17.6
16.2
1.41
1.8 2
2.18
2.56
2.59
2.61
15.57
1 8 .94
21.47
23.02
23.8 1
24.29
14.3
15.3
16.5
1 8 .0
17.2
15.7
1.62
2.12
2.54
2.78
2.8 2
2.8 4
61
64
6 8
70
72
75
4.50
4.59
4.71
4.77
4.8 2
4.79
24.15
24.11
24.06
24.03
24.01
23.59
26.64
26.60
26.55
26.00
25.04
23.59
4.69
4.77
4.8 7
4.77
4.55
4.23
30.33
2 8 . 8 9
26.96
26.00
25.04
23.59
4.88
4.59
4.22
4.04
3.8 6
3.60
30.33
2 8 . 8 9
26.96
26.00
25.04
23.59
4.26
4.02
3.70
3.54
3.39
3.16
30.33
2 8 . 8 9
26.96
26.00
25.04
23.59
3.94
3.72
3.43
3.29
3.15
2.94
(MBh)