1-15
English
4WV
A
OF
L
N
COMP
L
N
A
4WV
OF
COMP
N
L
Indoor Unit
Terminal Block
Interconnection Cable
Outdoor Unit
Terminal Block
Power Supply Cable
Outdoor Coil Sensor
Model Indoor (FCQN) 50E 60E 71E
Outdoor (RYN/RQ) 50C 60C 71C
Voltage range** Indoor (FCQN)
220-240V/1Ph/50Hz + !
Outdoor (RYN/RQ)
220-240V/1Ph/50Hz + !
Power supply cable size* (mm
2
)
Number of conductors
2.5
3
2.5
3
4.0
3
Interconnection cable size* (mm
2
)
Number of conductors
2.5
5
2.5
5
2.5
5
Recommended time delay fuse* (A) 13 18 25
FCQN 100E - RQ 90/100D (1 PH)
There must be an all pole disconnection
in the supply mains with a contact
separation of at least 3mm.
4WV
OF
COMP
N
OF
4WV
COMP
L
N
N1
Indoor Unit
Terminal Block
Interconnection Cable
Outdoor Unit
Terminal Block
Power Supply Cable
Outdoor Coil Sensor
FCQN 50/60E - RYN 50/60C (1 PH)
FCQN 71E - RQ 71C (1 PH)
There must be an all pole disconnection
in the supply mains with a contact
separation of at least 3mm.
1 IM-5CKE-0912(0)DAIKIN-EN.indd 151 IM-5CKE-0912(0)DAIKIN-EN.indd 15 9/28/12 2:04:18 PM9/28/12 2:04:18 PM