INSTALLATION
MANUAL
MODELS
FCRN50EXV1 RN50C(G)XV1
FCRN60EXV1 RN60C(G)XV1
FCRN71EXV1 RR71C(G)XV1
FCRN100EXV1 RR90D(G)XV1
FCRN125EXV1 RR90D(G)XY1
RR100D(G)XV1
FCQN50EXV1 RR100D(G)XY1
FCQN60EXV1 RR125D(G)XY1
FCQN71EXV1
FCQN100EXV1 RYN50C(G)XV1
FCQN125EXV1 RYN60C(G)XV1
RQ71C(G)XV1
RQ90D(G)XV1
RQ90D(G)XY1
RQ100D(G)XV1
RQ100D(G)XY1
RQ125D(G)XY1
CEILING CASSETTE
R410A SPLIT TYPE AIR CONDITIONER
(E Series)
IM-5CKE-0912(0)DAIKIN
Part No.: R08019038169
English
Français
Deutsch
Italiano
Español
Русский
Türkçe
Installation Manual
R410A Split Type Air Conditioner
Manuel D’installation
Climatiseurs Split System R410A
Installationshandbuch
Doppelfunktions-Klimagerät and R410A
Manuale Di Installazione
Condizionatore Split A R410A
Manual De Instalación
Equipo de air Acondicionado de tipo
Dividido de R410A
Руководство по установке
R410A разделить Кондиционер
воздуха типа
Kurulum kılavuzu
R410A Split Tipi Klima
CVR 5CKE-0912(0)DAIKIN-EN.indd 1CVR 5CKE-0912(0)DAIKIN-EN.indd 1 9/27/12 12:12:39 PM9/27/12 12:12:39 PM

Questions and Answers

  • C
    Corey DavisAug 3, 2025
    Why my Daikin Air Conditioner unit does not operate?
    • B
      bmccormickAug 3, 2025
      If your Daikin Air Conditioner unit isn't operating, first, check for a power failure or a blown fuse and replace the fuse if needed. Next, ensure the power plug is properly connected. Finally, verify that the delay timer is correctly set.
  • K
    Kevin SmithAug 8, 2025
    What to do if water flowing out from Daikin FCRN50EXV1 Air Conditioner unit?
    • E
      Erika DouglasAug 8, 2025
      If water is flowing out from your Daikin Air Conditioner unit, switch it off and call your local dealer or a qualified serviceman.
  • A
    apowellAug 15, 2025
    How to fix bad odor from Daikin FCRN50EXV1?
    • R
      rebecca63Aug 15, 2025
      If your Daikin Air Conditioner discharge air flow has a bad odor, the odors may be caused by cigarettes, smoke particles, perfume etc. which might have adhered onto the coil. Clean the coil to remove any adhered substances.
  • R
    Ruth ReyesAug 21, 2025
    Why is the air flow too low in my Daikin FCRN50EXV1 Air Conditioner?
    • J
      Jose RomeroAug 21, 2025
      Low airflow in your Daikin Air Conditioner can be due to a few reasons. First, check if the air filter is dirty and clean it. Second, make sure that the air suction and discharge are not clogged. Finally, if you're in auto fan mode, the regulated temperature might not be high enough, so try increasing it.
  • B
    Barbara GonzalezAug 27, 2025
    What to do if there is condensation on Daikin Air Conditioner?
    • Y
      youngtonyAug 27, 2025
      Condensation on the front air grille of your Daikin Air Conditioner's indoor unit is typically due to air humidity after extended operation. To address this, increase the temperature setting and operate the unit at high fan speed.

Summary

Outline and Dimensions

Safety Precautions and Notices

General Safety Warnings

Outlines critical safety warnings for installation and operation.

Cautions for Installation

Highlights important cautions to observe during the installation process.

Refrigerant Information

Indoor Unit Installation Procedures

Electrical Wiring Installation (Indoor Unit)

Outdoor Unit Installation Requirements

Installation Clearances and Piping Specs

Piping Works and Flaring Technique

Flaring and Torque Specifications

Explains the flaring process and required torque for connections.

Electrical Wiring Diagrams (Single Phase)

Electrical Wiring Diagrams (3 Phase)

Electrical Wiring Diagrams (FCQN Models)

Electrical Wiring Diagrams (FCQN 3 Phase)

Electrical Wiring Precautions

General Wiring Best Practices

Guidelines for secure and safe electrical connections.

R410 A Refrigerant Handling Precautions

Special safety measures for handling R410A refrigerant.

Vacuuming and Refrigerant Charging

Vacuuming the System

Procedure for evacuating air and moisture from the system.

Refrigerant Charging Operation

Steps for charging the unit with the correct amount of refrigerant.

Additional Refrigerant Charge

Scroll Compressor Charging Precautions

Specific precautions for charging units with scroll compressors.

Refrigerant Charging Procedures

Single Phase Compressor Charging

Detailed charging procedure for single-phase compressors.

Three Phase Compressor Charging

Detailed charging procedure for three-phase compressors.

Fault Diagnosis and Operating Range

Fault Diagnosis Codes

Explains error codes indicated by controller LEDs.

Final Checks and Phase Protection

Phase Protector Functionality

Explains the phase protector and its LED indicators.

Service, Maintenance, and Troubleshooting

Service and Maintenance Guidelines

Procedures for cleaning filters and indoor unit parts.

Troubleshooting Guide

Lists common faults, causes, and actions for resolution.