1-14
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
FDM50JEVLK - RD50JETLK
FDM60JEVLK - RD60JETLK
Power Supply Cable
Interconnection
cable
Outdoor unit
Terminal Block
Indoor unit
Terminal Block
Model Indoor FDM50JEVLK FDM60JEVLK
Outdoor RD50JETLK RD60JETLK
Voltage range**
Indoor
220V/1Ph/60Hz+!
Outdoor
220V/3N~/60Hz+!
Power supply cable size* mm
2
Number of conductors
6.0
4
6.0
4
Interconnection cable size* mm
2
Number of conductors
2.5
4
2.5
4
Recommended time delay fuse* A 35 35
Model Indoor FDM40JEVLK
Outdoor RD40JEVLK
Voltage range**
Indoor
220V/1Ph/60Hz+!
Outdoor
220V/1Ph/60Hz+!
Power supply cable size* mm
2
Number of conductors
6.0
3
Interconnection cable size* mm
2
Number of conductors
2.5
4
Recommended time delay fuse* A 35
Power Supply Cable
Interconnection cable
Outdoor unit
Terminal Block
Indoor unit
Terminal Block
FDM40JEVLK - RD40JEVLK
N
L
COMP
N
L
N
L
COMP
T
S
R
N
L
COMP
N
L
COMP
There must be an all pole
disconnection in the supply
mains with a contact separation
of at least 3mm.
!
N
1 IM-CCC-0311(0)-DAIKIN (SASO).i14 14 6/9/11 10:07:40 AM