EasyManua.ls Logo

Daikin FDYA160AV1 User Manual

Daikin FDYA160AV1
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION MANUAL
DUCTED SYSTEM
R-32 Series
Air Conditioners
MODELS
(Ceiling concealed duct type)
FDYAN50/60/71/85/100/125/140/160AV1
FDYA71/85/100/125/140/160AV1
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
Question and Answer IconNeed help?

Do you have a question about the Daikin FDYA160AV1 and is the answer not in the manual?

Daikin FDYA160AV1 Specifications

General IconGeneral
BrandDaikin
ModelFDYA160AV1
CategoryAir Conditioner
LanguageEnglish

Summary

SAFETY CONSIDERATIONS

General Safety Warnings

Observe all warnings and cautions for safe installation and operation, preventing death, injury, or damage.

Installation Environment Precautions

Precautions for suitable installation environments, avoiding kitchens, corrosive gas, flammable vapors, and high humidity.

Electrical Safety Precautions

Ensures electrical safety through proper wiring, grounding, circuit breakers, and preventing contact with water.

Refrigerant Piping Safety

Use only approved R32 piping and handle refrigerant carefully to prevent leaks, explosions, or system malfunction.

BEFORE INSTALLATION

Handling and Transport

Guidelines for safe handling, moving, and checking refrigerant type before installation.

Installation Site Precautions

Precautions for suitable installation environments and avoiding specific hazardous conditions like kitchens or corrosive gases.

Included and Optional Accessories

Lists included accessories and mentions optional items like remote controllers and hanging brackets.

NOTE TO THE INSTALLER

Post-Installation Checks

Checklist of essential items to verify after installation for proper operation and safety.

Customer Handover

Procedures for demonstrating unit operation and providing the operation manual to the customer.

SELECTING INSTALLATION SITE

Site Selection Criteria

Criteria for choosing an installation site, ensuring proper air distribution, drainage, and structural support.

Site Specific Cautions

Cautions regarding electrical interference and secure installation using suspension bolts.

PREPARATION BEFORE INSTALLATION

Unit Preparation and Notes

Instructions on unit disassembly for easier handling and important notes on service space and insulation.

INDOOR UNIT INSTALLATION

Suspension Bolt Installation

Steps for installing suspension bolts, anchors, and hanging brackets for unit mounting.

Unit Levelling and Securing

Procedure for ensuring the indoor unit is level and securely fastened using nuts and washers.

REFRIGERANT PIPING WORK

Piping Insulation and Material

Importance of insulating refrigerant pipes and using R32 rated materials to prevent leaks and damage.

Refrigerant Handling Precautions

Precautions to avoid contaminants in refrigerant piping and ensure proper ventilation during installation.

Flare Nut Connection

Instructions for correctly connecting flare nuts using torque wrenches and appropriate coatings.

Brazing Precautions

Guidelines for brazing refrigerant piping using flux-free filler metal and dry nitrogen gas.

Emergency Tightening

Method for tightening flare nuts without a torque wrench in emergency situations.

DRAIN PIPING WORK

Drain Piping Installation

Steps for installing drain pipes, ensuring proper slope, securing, and insulation to prevent leaks.

Drain Piping Connections

Caution against connecting drain piping directly to sewage pipes to prevent corrosion and odor issues.

Drainage Flow Check

Procedure to verify smooth drainage flow by pouring water into the drain tray.

ELECTRICAL WIRING WORK

Wiring Compliance and Materials

Requirements for electrical wiring, including adherence to local codes and using specified materials.

Wiring Connections and Safety

Details on connecting remote controllers, installing circuit breakers, and ensuring proper earthing for safety.

Wiring Protection

Guidelines for protecting wiring using shield wire, double insulation, and conduits against external forces and noise.

Wiring Diagram and Connections

Detailed wiring instructions referring to diagrams for power, earth, and inter-unit transmission connections.

PRECAUTIONS (for wiring)

Site Wiring Precautions

Precautions for wiring, including phase selection, cord management, and wire separation to prevent interference.

Power Supply Wiring Precautions

Precautions for power supply wiring, focusing on correct terminal connections and wire gauge usage.

Wire Connection Security

Ensuring secure wire connections, proper terminal box cover fitting, and cable management.

WIRING EXAMPLE

System Type Wiring Examples

Examples of wiring configurations for single-phase, dual-remote, and group control systems.

System Wiring Diagrams

Visual diagrams illustrating wiring for single-phase, dual-remote, and group control system types.

Wiring Notes and Guidelines

Important notes and guidelines for wiring, including shielded wire usage, grounding, and group control configurations.

Field Settings

Changing Field Settings

Procedure to modify indoor unit settings like fan speed, sensor location, and thermostat through the remote controller.

Setting Items Overview

Overview of adjustable field settings including fan speed, filter sign, sensor location, and thermostat parameters.

Wired Remote Controller Operations

Steps to access service settings and navigate field settings using the remote controller.

FAN MANUAL SETTING

DC Fan Motor Operation

Explanation of the DC Fan Motor's operation and its management system.

Target Fan Speed Adjustment

Instructions for commissioning the target fan motor speed to individual settings.

HOW TO SET FAN AUTOMATIC ADJUSTMENT

Automatic Airflow Adjustment Steps

Step-by-step guide to perform automatic airflow adjustment using the remote controller.

Confirming Automatic Airflow Adjustment

Steps to confirm successful automatic airflow adjustment and troubleshooting common failure reasons.

Automatic Airflow Adjustment Failure Reasons

Potential reasons why automatic airflow adjustment might fail, such as external static or duct instability.

OTHER SETTINGS

Air Filter Sign Setting

Configuration for the air filter sign indication, enabling or disabling alerts.

Temperature Sensor Location

Setting the location of the temperature sensor (indoor unit, remote controller, or alternate).

Indoor Fan Settings

Adjusting indoor fan speed settings during heating and cooling thermo-off modes.

T1, T2 Input Setting

Configuration options for T1, T2 input settings, including forced off and ON/OFF operation.

Thermostat Sensor and Permission Level

Settings for thermostat sensor location in the remote controller and user permission levels.

Setback Function Settings

Configuration options for the setback function, including heating only, cooling only, and both.

CONTROL BY 2 REMOTE CONTROLLERS

Wiring Check and Power-On

Pre-power-on checks for indoor/outdoor unit wiring and electrical box covers.

Setting Sub Remote Controller

Procedure for setting the sub remote controller when one indoor unit is controlled by two remotes.

Error Code U5 Indication

Explanation of Error Code U5 appearing if the sub remote controller is not set correctly.

SEPARATING THE INDOOR UNIT FOR ALL MODELS

Indoor Unit Disassembly Steps

Detailed steps for safely disassembling the indoor unit, separating the airbox and fan deck compartments.

Indoor Unit Reassembly Steps

Step-by-step instructions for correctly reassembling the indoor unit after disassembly.

ERROR CODE LIST

INDOOR Unit Error Codes

Table detailing error codes and their causes for the indoor unit.

OUTDOOR Unit Error Codes

Table detailing error codes and their causes for the outdoor unit.

SYSTEM Error Codes

Table detailing error codes and their causes for the overall system.

Related product manuals