Details troubleshooting steps when equipment fails to operate.
Addresses scenarios where the indoor fan works but the compressor does not.
Troubleshooting for operations that start and then stop abruptly.
Diagnosing issues with delayed unit restarts after shutdown.
Troubleshooting for units that run but don't cool.
Troubleshooting for units that run but don't heat.
Addresses abnormalities with the indoor unit PCB, indicated by error code A1.
Troubleshooting transmission errors between indoor unit PCB and fan PCB, indicated by error code C1.
Troubleshooting transmission errors between indoor unit PCB and adaptor PCB, indicated by error code C1.
Troubleshooting abnormalities with the outdoor unit PCB, indicated by error code E1.
Troubleshooting compressor motor lock, indicated by error code E5.
Troubleshooting compressor overcurrent, indicated by error code E6.
Troubleshooting abnormalities with the outdoor unit PCB, indicated by error code L1.
Troubleshooting abnormalities with the outdoor inverter PCB, indicated by error code L1.
Troubleshooting abnormalities with the outdoor unit PCB, indicated by error code L1.
Addresses instantaneous overcurrent of DC output, indicated by error code L4.
Addresses instantaneous overcurrent of DC output, indicated by error code L5.
Troubleshooting momentary overcurrent of the inverter compressor, indicated by error code L5.
Addresses output overcurrent detection, indicated by error code L5.
Addresses output overcurrent detection, indicated by error code L5.
Addresses output overcurrent detection, indicated by error code L5.
Troubleshooting overcurrent in the inverter compressor, indicated by error code L8.
Troubleshooting transmission errors between inverter and control PCB, indicated by error code LC.
Troubleshooting transmission errors between control and inverter PCBs, indicated by error code LC.
Troubleshooting refrigerant shortage, indicated by error code U0.
Troubleshooting refrigerant shortage, indicated by error code U0.
Troubleshooting transmission errors between indoor and outdoor units, indicated by error codes U4 or UF.
Troubleshooting transmission errors between indoor and outdoor units, indicated by error code U4.
Troubleshooting transmission errors between indoor unit and remote controller, indicated by error code U5.
Troubleshooting transmission errors between outdoor units, indicated by error code U7.
Troubleshooting transmission errors between main and sub remote controllers, indicated by error code U8.
Troubleshooting transmission errors between indoor/outdoor units in the same system, indicated by error code U9.
Troubleshooting improper combinations of indoor/outdoor units and remote controllers, indicated by error code UA.
Troubleshooting transmission errors between centralized controller and indoor unit, indicated by error code UE.
Troubleshooting transmission errors, piping/wiring mismatches, and refrigerant shortage, indicated by error code UF.
Troubleshooting transmission system abnormalities between indoor and outdoor units, indicated by error code UF.