3. OPERATION RANGE
If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the
air conditioner may not operate, or sometimes,
water may drop from the indoor unit.
COOLING C]*
* To avoid condensation and water dripping out the indoor unit.
DB: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the remote controller is 16°C
to 32°C depends on heating/cooling mode.
OUTDOOR UNIT
INDOOR
OUTDOOR
TEMPERA-
TURE
TEMPERA-
TURE
HUMID-
ITY
RN50
RN60
DB 18 to 32
80%*or
below
DB
– 10 to
46
RKS35/50/60
RXS35/50/60
DB 18 to 32
80%*or
below
DB
– 10 to
46
4MKS58/75
3MXS52/68
4MXS68/80
5MXS90
DB 18 to 32
80%*or
below
DB
– 10 to
46
5MKS90
DB 18 to 32
80%*or
below
DB 10 to 46
RZQ140/200/
250
DB 20 to 37
80%*or
below
DB – 5 to 46
WB 14 to 28
RZQG
71/100/
125/140
DB 18 to 37
80%*or
below
DB
– 15 to
50
WB 12 to 28
RZQSG 71/100/
125 /140
DB 20 to 37
80%*or
below
DB
– 15 to
46
WB 14 to 28
OUTDOOR UNIT
INDOOR
OUTDOOR
TEMPERA-
TURE
TEMPERA-
TURE
HUMID-
ITY
RXM35/50/60
DB 18 to 32
80%*or
below
DB
– 10 to
46
3MXM40/52/68
4MXM68/80
5MXM90
DB 18 to 32
80%*or
below
DB
– 10 to
46
RZAG71/100/
125/140
DB 18 to 37
80%*or
below
DB
– 20 to
52
WB 12 to 28
RZASG71/100/
125/140
DB 20 to 37
80%*or
below
DB
– 15 to
46
WB 14 to 28
HEATING C]*
* To avoid condensation and water dripping out the indoor unit.
DB: Dry bulb temperature
WB: Wet bulb temperature
The setting temperature range of the remote controller is 16°C
to 32°C depends on heating/cooling mode.
4. INSTALLATION SITE
Regarding places for installation
Is the air conditioner installed at a well-ventilated
place where there are no obstacles around?
Do not use the air conditioner in the following
places.
a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring
resort
d. Where there are considerable voltage fluctua-
tions such as a factory or plant
e. Vehicles and vessels
f. Where there is much spray of oil and vapor
such as a cookery, etc.
g. Where there are machines generating electro-
magnetic waves
h. Filled with acid and/or alkaline steam or vapor
OUTDOOR UNIT
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
RXS35/50/60
DB 10 to 30
DB – 15 to 24
WB – 16 to 18
3MXS52/68
4MXS68/80
5MXS90
DB 10 to 30
DB
– 15 to 24
WB – 16 to 18
RZQG71/100/
125/140
DB 10 to 27
DB –19.5 to 21
WB –20 to 15.5
RZQ200/250
DB 10 to 27
DB – 14 to 21
WB – 15 to 15
RZQSG71
DB 10 to 27
DB – 14 to 21
WB –15 to 15.5
RZQSG100/125/
140
DB 10 to 27
DB – 14 to 21
WB –15 to 15.5
RZQ140
DB 10 to 27
DB – 19.5 to 21
WB – 20 to 15.5
OUTDOOR UNIT
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
RXM35/50/60
DB 10 to 30
DB – 15 to 24
WB – 16 to 18
3MXM40/52/68
4MXM68/80
5MXM90
DB 10 to 30
DB
– 15 to 24
WB – 16 to 18
RZAG71/100/125/
140
DB 10 to 27
DB – 19.5 to 21
WB – 20 to 15.5
RZASG71/100/125/
140
DB 10 to 27
DB – 14 to 21
WB – 15 to 15.5