ELECTRICAL SPECIFICATIONS
For indoor units only: FLXS25BVMB FLXS35BVMB FLXS50BVMB FLXS60BVMB
CURRENT Nominal running current
cooling/heating
A 0.32/0.34 0.36/0.36 0.45/0.45 0.45/0.43
Maximum running current
cooling/heating
A See chapter RXS-B: electrical data
For combination indoor units + outdoor units: FLXS25BVMB FLXS35BVMB FLXS50BVMB FLXS60BVMB
RXS25BVMB RXS35BVMB RXS50BVMB Multi appl. only
CURRENT Nominal running current
cooling/heating
A 3.8/4.5 5.7/6.3 7.6/8.0 -
Maximum running current
cooling/heating
A
See chapter RXS-B: electrical data
Starting current
cooling/heating
A
For combination indoor units + outdoor units: FLXS25BVMB FLXS35BVMB
RX25BVMB RX35BVMB
CURRENT Nominal running current
cooling/heating
A 4.2/4.9 5.9/6.0
Maximum running current
cooling/heating
A
See chapter RX-B: electrical data
Starting current
cooling/heating
A
For combination indoor units + outdoor units: FLXS25BVMB FLXS35BVMB FLXS50BVMB FLXS60BVMB
2MXS40/3MXS52/4MXS68,80B 3MXS52/4MXS68,80B 4MXS68,80B
CURRENT Nominal running current
cooling/heating
A
See chapter MXS-B: electrical dataMaximum running current
cooling/heating
A
Starting current
cooling/heating
A
For indoor units only: FLXS25BVMB FLXS35BVMB FLXS50BVMB FLXS60BVMB
POWER SUPPLY VM VM VM VM
NOMINAL DISTRIBUTION SYSTEM
VOLTAGE
Phase 1 1 1 1
Frequency Hz 50 50 50 50
Voltage V 230 230 230 230
NOTES
1 Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB * outdoor temperature 35°CDB * refrigerant piping length: 7.5m *
level difference: 0m.
2 Nominal heating capacities are based on: indoor temperature: 20°CDB * outdoor temperature: 7°CDB/6°CWB * refrigerant piping length: 7.5m *
level difference 0m.
3 Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
4 Units should be selected on nominal capacity. Maximum capacity is limited to peak periods.
5 The sound pressure level is measured via a microphone at a certain distance from the unit. For measuring conditions: please refer to item 6 of this
chapter.
6 The sound power level is an absolute value indicating the ’’power’’ which a sound source generates.
7 Energy label: scale from A (most efficient) to G (less efficient).
8 Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)
Flexi Type, Inverter Controlled Unit R-410A FLK/XS25,35,50,60BVMB
2
Specifications
1
2
8
Split - Sky Air Indoor units