5 Energy saving and optimum operation
Operation manual
5
FNA25~60A2VEB
Split system air conditioners
4P456953-1 – 2017.06
5 Energy saving and optimum
operation
CAUTION
This unit is equipped with electrically powered safety
measures, such as a refrigerant leak detector. In order to
be effective, the unit must be electrically powered at all
times after installation, except for short service periods.
1
Observe the following precautions to ensure the system operates
properly.
Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.
Ventilate often. Extended use requires special attention to
ventilation.
Keep doors and windows closed. If the doors and windows remain
open, air will flow out of your room causing a decrease in the
cooling or heating effect.
Be careful not to cool or heat too much. To save energy, keep the
temperature setting at a moderate level.
Never place objects near the air inlet or the air outlet of the unit. It
may cause deterioration in the effect or stop the operation.
When the display shows (time to clean the air filter), clean the
filters (see "6.2.3To clean the air filter"on page6).
Keep the indoor unit and user interface at least 1 m away from
televisions, radios, stereos, and other similar equipment. Failing to
do so may cause static or distorted pictures.
Do NOT place items under the indoor unit, as they may be
damaged by water.
Condensation may form if the humidity is above 80% or if the
drain outlet gets blocked.
6 Maintenance and service
6.1 Overview: Maintenance and
service
The installer has to perform a yearly maintenance.
About the refrigerant
This product contains fluorinated greenhouse gases. Do NOT vent
gases into the atmosphere.
Refrigerant type: R32
Global warming potential (GWP) value: 675
Refrigerant type: R410A
Global warming potential (GWP) value: 2087.5
NOTICE
In Europe, the greenhouse gas emissions of the total
refrigerant charge in the system (expressed as tonnes
CO
2
-equivalent) is used to determine the maintenance
intervals. Follow the applicable legislation.
Formula to calculate the greenhouse gas emissions:
GWP value of the refrigerant × Total refrigerant charge [in
kg] / 1000
Please contact your installer for more information.
WARNING
R410A is a non-combustible refrigerant, and R32 is a
mildly flammable refrigerant; they normally don’t leak. If the
refrigerant leaks in the room and comes in contact with fire
from a burner, a heater, or a cooker, this may result in a
fire (in case of R32), or the formation of a harmful gas.
Turn off any combustible heating devices, ventilate the
room, and contact the dealer from where you purchased
the unit.
Do not use the unit until a service person confirms that the
part from which the refrigerant leaked has been repaired.
WARNING
Do NOT pierce or burn refrigerant cycle parts.
Do NOT use cleaning materials or means to accelerate
the defrosting process other than those recommended
by the manufacturer.
Be aware that the refrigerant inside the system is
odourless.
NOTICE
Maintenance MUST be done by an authorized installer or
service agent.
We recommend performing maintenance at least once a
year. However, applicable legislation might require shorter
maintenance intervals.
DANGER: RISK OF ELECTROCUTION
To clean the air conditioner or air filter, be sure to stop
operation and turn all power supplies off. Otherwise, an
electric shock and injury may result.
In case the unit is equipped with a refrigerant leakage
sensor, turn the power supply breaker back on
immediately after cleaning in order to maintain
detection functionality.
WARNING
To prevent electric shocks or fire:
Do NOT rinse the unit.
Do NOT operate the unit with wet hands.
Do NOT place any objects containing water on the unit.
CAUTION
After a long use, check the unit stand and fitting for
damage. If damaged, the unit may fall and result in injury.
CAUTION
Do not touch the heat exchanger fins. These fins are sharp
and could result in cutting injuries.
NOTICE
When cleaning the heat exchanger, make sure to remove
the switch box and fan motor. Water or detergent might
deteriorate the insulation of electronic components and
result in burnout of these components.
WARNING
Be carefull with ladders when working in high places.
(1)