9
To set the clock
1. Press “CLOCK button”.
is displayed.
blinks.
2. Press “TIMER setting button”
to set the clock to the present
time.
Holding down or “” button rap-
idly increases or decreases the time dis-
play.
3. Press “CLOCK button”.
blinks.
Turn the breaker ON
Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
NOTE
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
Clogged air filters cause inefficient operation and waste energy. Clean them
once in about every two weeks.
Please note
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
Use the air conditioner in the following conditions.
Operation outside this humidity or temperature range may cause a safety device to disable the system.
C
TEMP
ON/OFF
POWERFUL
HOME LEAVE
MODE
TIMER
FAN
SILENT
SWING
ON
CANCEL
OFF
SENSOR
1.3
2
Recommended temperature setting
For cooling:26
°
C 28
°
°°
°
C
For heating:20
°
C 24
°
C
Mode Operating conditions If operation is continued out of this range
COOL
Outdoor temperature:3/4MK10 to 46 °C
3/4MX10 to 46 °C
RK(X)5 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of the out-
door unit only.)
Condensation may occur on the indoor unit and drip.
HEAT
Outdoor temperature:3/4MX 15 to 21 °C
RX15 to 24 °C
Indoor temperature: 10 to 30 °C
A safety device may work to stop the operation.
DRY
Outdoor temperature:3/4MK10 to 46 °C
3/4MX10 to 46 °C
RK(X)5 to 46 °C
Indoor temperature: 18 to 32 °C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
01_EN_3P098595-2N.fm Page 9 Tuesday, July 5, 2005 5:32 PM

Other manuals for Daikin FTKD60BVMA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTKD60BVMA and is the answer not in the manual?

Daikin FTKD60BVMA Specifications

General IconGeneral
BrandDaikin
ModelFTKD60BVMA
CategoryAir Conditioner
LanguageEnglish

Related product manuals