3 Check the power supply to the unit, see "3.1.1Checking procedures"[4156].
Does the unit receive power? Action
Yes Replace the main PCB, see "Repair
procedures"[4108].
No Adjust the power supply to the unit, see
"3.1.2Repair procedures"[4157].
To check the HAP LED of the main PCB
Prerequisite: First check the power supply to the main PCB, see "Checking
procedures"[499].
1 Locate the HAP LED on the main PCB.
A
a
A RXA42~50A unit
a HAP LED
aA
A RXA42~50B unit
a HAP LED
INFORMATION
Make sure the correct software is available on the PCB. If NOT, update using the
updater tool.